Do you have any question about this error?
Message type: E = Error
Message class: SV - View Maintenance: Customize Messages
Message number: 585
Message text: The view cluster contains subdialogs with and w/o navigation subscreens.
From Release 46A view cluster navigation uses a Tree Control.
The navigation subscreen is no longer put in the view maintenance
screens of new maintenance dialogs in a modified view cluster when it
activated. Existing subscreens are dynamically compressed away at
runtime.
This view cluster &V1& contains maintenance dialogs both with and
without navigation subscreens.
The view cluster is activated nevertheless. The navigation subscreens
are not active at runtime.
You can delete the navigation subscreens in the view maintenance
screens as follows:
Reactivate the view cluster and confirm the deletion of the subscreen
in the 'View cluster navigation' popup.
Use the program <LS>RSVCLNAVI</> to delete the navigation subscreen
from the screen.
The program can also edit all the view clusters in a package.
You can also delete the subscreens from the view maintenance dialogs
manually in the Screen Painter.
Note:
Navigation subscreens in maintenance dialog detail screens must always
be removed manually in the Screen Painter, because they are not
inserted automatically. User modules for navigating in detail screens
must also be removed manually.
Possible incompatibilities using the Tree Control:
Manipulation in user-defined events of the global internal table
<LS>VCL_STRUC_TAB</> to influence the navigation subscreen structure
may not affect the Tree Control structure.
Error message extract from SAP system. Copyright SAP SE.
SV585
- The view cluster contains subdialogs with and w/o navigation subscreens. ?The SAP error message SV585 indicates that there is an issue with a view cluster that contains subdialogs, some of which have navigation subscreens while others do not. This inconsistency can lead to problems in the user interface and functionality of the application.
Cause:
The error typically arises when:
- A view cluster is designed with subdialogs that are not uniform in their configuration regarding navigation subscreens.
- Some subdialogs are set up to use navigation subscreens, while others are not, leading to a conflict in how the view cluster is expected to behave.
Solution:
To resolve this error, you can take the following steps:
Review the View Cluster Configuration:
- Go to the transaction code SE80 (Object Navigator) or SE11 (Data Dictionary) and locate the view cluster in question.
- Check the configuration of each subdialog to ensure that they are consistent in their use of navigation subscreens.
Modify Subdialog Settings:
- If you find that some subdialogs are using navigation subscreens while others are not, you will need to modify the settings to ensure uniformity.
- Either convert all subdialogs to use navigation subscreens or remove navigation subscreens from those that currently have them.
Testing:
- After making the necessary changes, test the view cluster to ensure that the error no longer occurs and that the functionality is as expected.
Documentation:
- Document any changes made for future reference and to assist other developers or users who may encounter similar issues.
Related Information:
By ensuring that all subdialogs within the view cluster are configured consistently, you should be able to resolve the SV585 error and restore proper functionality to the application.
Get instant SAP help. Start your 7-day free trial now.
SV584
& is a view cluster variant
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
SV583
Field-dependence type 'I' for field & of object & is not allowed.
What causes this issue? &V1& was specified as field name in a field relationship of type 'I' for the object &V2&, but the f...
SV586
Dynpro & could not be activated.
What causes this issue? Screen &V1& has been modified for view cluster maintenance and saved. Screen activation errors occurred, which could ...
SV587
Object & is a maintenance view variant. Dynpro was not changed.
What causes this issue? The object &V1& is a maintenance view variant of &V2& so it has no maintenance screens of its own.System Resp...
Click on this link to search all SAP messages.