Do you have any question about this error?
Message type: E = Error
Message class: RSDRO - ODS Update/Activation
Message number: 306
Message text: There are more than 10 char. values that could NOT be assigned a SID
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
No additional logs are written for the additional errors.
Error message extract from SAP system. Copyright SAP SE.
RSDRO306
- There are more than 10 char. values that could NOT be assigned a SID ?The SAP error message RSDRO306 indicates that there are more than 10 characteristic values in a characteristic that could not be assigned a SID (Surrogate ID). This typically occurs in the context of SAP BW (Business Warehouse) when loading data into InfoObjects, particularly when the system encounters issues with the mapping of characteristic values to their corresponding SIDs.
Causes:
Too Many Unique Values: The characteristic has more than 10 unique values that are not yet assigned a SID. This can happen if the data being loaded contains many distinct values that have not been previously defined in the master data.
Master Data Not Loaded: The master data for the characteristic may not have been loaded or activated, which means that the system cannot find existing SIDs for the new values.
Data Quality Issues: There may be issues with the data quality, such as leading/trailing spaces, inconsistent casing, or special characters that prevent the system from recognizing the values.
Configuration Issues: The InfoObject may not be properly configured to handle the incoming data, or there may be issues with the data source.
Solutions:
Load Master Data: Ensure that the master data for the characteristic is loaded and activated before loading the transactional data. This will allow the system to assign SIDs to the characteristic values.
Check Data Quality: Review the data being loaded for any inconsistencies or formatting issues. Clean the data to ensure that it matches the expected format for the characteristic.
Increase SID Assignment Limit: If necessary, you can adjust the settings in the InfoObject to allow for more than 10 values to be assigned SIDs. However, this should be done with caution and understanding of the implications.
Use a Data Transfer Process (DTP): If you are using a DTP to load data, ensure that it is correctly configured to handle the characteristic values and that it is set to update the master data.
Check for Existing SIDs: Use transaction RSD1 to check the InfoObject and see if the existing SIDs are correctly assigned. You can also use transaction RSD3 to analyze the SID table.
Reprocess the Data Load: After addressing the above issues, reprocess the data load to see if the error persists.
Related Information:
By following these steps, you should be able to resolve the RSDRO306 error and successfully load your data into SAP BW.
Get instant SAP help. Start your 7-day free trial now.
RSDRO305
For details, see long text
What causes this issue? Characteristic Value: &v1& Request: &v2& Data package: &v3& Data record: &v4& The system issu...
RSDRO304
Specification '&1' for InfoObject '&2' not permitted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDRO307
No data can be loaded for which no master data exists
What causes this issue? When loading requests that need to receive your master data ID, it was specified in the scheduler that data still having no m...
RSDRO330
Error when reading the generated program &1 / &2
What causes this issue? Errors occurred when reading the generated program in program &v1& with action &v2&.System Response sy1:&...
Click on this link to search all SAP messages.