Do you have any question about this error?
Message type: E = Error
Message class: RSDD - Message class for data manager
Message number: 723
Message text: Delta hierarchy changes for &2 (source &1), read &3, wrote &4
In the change run, changes were made for the aggregate for
characteristic &V2&. The source for the delta records was the
aggregate/ InfoCube &V1&.
&V3& records were read and &V4& records were written.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RSDD723
- Delta hierarchy changes for &2 (source &1), read &3, wrote &4 ?The SAP error message RSDD723 typically occurs in the context of SAP BW (Business Warehouse) when there are issues related to delta hierarchy changes in InfoObjects. This error indicates that there is a mismatch between the data being read and the data being written for a delta hierarchy.
Cause:
The error message RSDD723 can be caused by several factors, including:
- Hierarchy Changes: Changes made to the hierarchy structure (like adding or removing nodes) that are not properly reflected in the delta process.
- Inconsistent Data: The data being read from the source (source &1) does not match the data being written (wrote &4), which can happen if there are inconsistencies in the hierarchy data.
- Delta Process Issues: Problems in the delta extraction process, such as incorrect delta initialization or issues with the delta queue.
- Data Load Issues: Issues during data loading that may lead to discrepancies in the hierarchy data.
Solution:
To resolve the RSDD723 error, you can follow these steps:
Check Hierarchy Changes: Review any recent changes made to the hierarchy structure in the source system. Ensure that these changes are correctly reflected in the BW system.
Reinitialize Delta: If there have been significant changes to the hierarchy, consider reinitializing the delta process. This can be done by:
- Deleting the existing delta initialization.
- Performing a full load of the data to ensure that the hierarchy is consistent.
Check Data Consistency: Verify the consistency of the data in the source system and the BW system. Ensure that the data being read matches the expected structure and values.
Monitor Delta Queue: Check the delta queue for any errors or inconsistencies. You can use transaction codes like RSA7 to monitor the delta queue and ensure that it is functioning correctly.
Review Logs: Look at the logs for the data load process to identify any specific errors or warnings that may provide more context about the issue.
Consult SAP Notes: Search for relevant SAP Notes that may address this specific error. SAP frequently updates its knowledge base with solutions for known issues.
Contact SAP Support: If the issue persists after trying the above steps, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the underlying cause of the RSDD723 error in your SAP BW environment.
Get instant SAP help. Start your 7-day free trial now.
RSDD722
Delta attribute changes for &2 (source &1), read &3, wrote &4
What causes this issue? In the change run, changes were made for the aggregate for characteristic &V2&. The source for the delta records was ...
RSDD721
Block &1: From SID &2 to SID &3 (with ChangeID = &4)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDD724
Block &1: Same SID &2 (with ChangeID = &4)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDD725
Condensing of aggregate &1 is terminated
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.