Do you have any question about this error?
Message type: E = Error
Message class: RSCRT - Near-To-Real-Time Messages
Message number: 111
Message text: A realtime data acquisition InfoPackage cannot create a repeat
InfoPackage &V1& is trying to generate a repeat request.
This is not allowed because the InfoPackage is a real-time data
acquisition InfoPackage.
This type of InfoPackage can only generate delta requests.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RSCRT111
- A realtime data acquisition InfoPackage cannot create a repeat ?The SAP error message RSCRT111 indicates that a real-time data acquisition InfoPackage cannot create a repeat. This error typically occurs in the context of SAP BW (Business Warehouse) when dealing with real-time data extraction from source systems.
Cause:
The error can be caused by several factors, including:
Data Source Configuration: The InfoPackage may not be correctly configured for real-time data acquisition. This could include issues with the data source settings or the extraction method.
Delta Mechanism Issues: If the delta mechanism is not set up properly, it can lead to problems in data extraction. This includes issues with the delta queue or the delta initialization.
Data Consistency: If there are inconsistencies in the data being extracted, such as missing records or issues with the data model, it can prevent the InfoPackage from processing correctly.
Technical Issues: There may be underlying technical issues, such as connectivity problems with the source system or issues with the BW system itself.
Solution:
To resolve the RSCRT111 error, you can take the following steps:
Check InfoPackage Settings: Review the settings of the InfoPackage to ensure that it is configured correctly for real-time data acquisition. Make sure that the data source is properly defined and that the extraction method is appropriate.
Verify Delta Configuration: Ensure that the delta mechanism is correctly set up. Check the delta queue for any issues and ensure that the delta initialization has been performed if required.
Monitor Data Consistency: Check the data in the source system for consistency. Ensure that there are no missing records or issues that could affect the extraction process.
Review Logs and Traces: Look at the logs and traces in SAP BW to identify any specific errors or warnings that could provide more context about the issue.
Check Connectivity: Ensure that there are no connectivity issues between the BW system and the source system. Test the connection to confirm that it is functioning properly.
Consult SAP Notes: Search for relevant SAP Notes that may address this specific error. SAP frequently releases updates and patches that can resolve known issues.
Reinitialize Delta: If necessary, you may need to reinitialize the delta for the data source to ensure that it is functioning correctly.
Related Information:
By following these steps, you should be able to diagnose and resolve the RSCRT111 error in your SAP BW environment.
Get instant SAP help. Start your 7-day free trial now.
RSCRT110
DTA '&1' does not exist in daemon Ctrl tab. - NOT updated
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSCRT109
Do you want to schedule the InfoPackage for RDA?
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSCRT112
In DataStore &1, load request &2(&3) is incorrectly activated
What causes this issue? Load request &V2&(&V3&) has not been successfully activated in DataStore object &V1&. The load reques...
RSCRT113
In DataStore &1, load request &2(&3) is incorrectly loaded
What causes this issue? Load request &V2&(&V3&) has not been successfully loaded in DataStore object &V1&. There is no data i...
Click on this link to search all SAP messages.