Message text: The top node of the monitor definition is invalid (not virtual type)
The top node of the monitor is invalid. It is not a virtual node. This
is caused by an internal error in the monitoring architecture.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Internal error. Contact the SAP Hotline.
Error message extract from SAP system. Copyright SAP SE.
RA259
- The top node of the monitor definition is invalid (not virtual type) ?The SAP error message RA259, which states "The top node of the monitor definition is invalid (not virtual type)," typically occurs in the context of SAP's monitoring and reporting tools, particularly when dealing with the configuration of monitoring definitions in the SAP system.
Cause:
The error is usually caused by one of the following issues:
Invalid Node Type: The top node of the monitor definition is not of a virtual type. In SAP, a virtual node is required as the starting point for certain monitoring definitions. If the top node is a physical node or of another type, the system will throw this error.
Configuration Issues: There may be a misconfiguration in the monitoring definition setup, where the hierarchy of nodes is not correctly defined.
Missing or Incorrect Definitions: The monitor definition may be referencing nodes or elements that do not exist or are incorrectly defined in the system.
Solution:
To resolve the RA259 error, you can take the following steps:
Check Node Type: Verify that the top node of your monitor definition is indeed a virtual type. You can do this by navigating to the relevant configuration area in SAP and checking the properties of the node.
Review Monitor Definition: Go through the entire monitor definition to ensure that all nodes are correctly defined and that the hierarchy is properly structured. Make sure that the top node is set as a virtual node.
Recreate the Monitor Definition: If the issue persists, consider deleting the current monitor definition and recreating it from scratch, ensuring that you select the correct node types during the setup process.
Consult Documentation: Refer to SAP documentation or help resources for specific guidelines on creating and managing monitor definitions. This can provide insights into the correct configurations and node types.
Check for Updates: Ensure that your SAP system is up to date with the latest patches and updates, as sometimes bugs in earlier versions can lead to unexpected errors.
Seek Help from SAP Support: If you are unable to resolve the issue, consider reaching out to SAP support for assistance. They can provide more detailed guidance based on your specific system configuration.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the RA259 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
RA258
Failed to generate a result node in rule call back &
What causes this issue? The system failed to generate a result node in the rule callback specified. This is caused by an internal error in the monito...
RA257
Monitor & already exists - new name required
What causes this issue? The monitor you have specified already exists.System Response The system issues an error message and will not allow you to c...
RA260
You must specify a system ID
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RA261
Unable to determine MTE data for class &1 of system &2
What causes this issue? MTE data could not be determined for the class in the specified system. There may be problems with the specified system. Thes...
Click on this link to search all SAP messages.