Do you have any question about this error?
Message type: E = Error
Message class: RA - Monitoring structure dialog message
Message number: 174
Message text: Data for the source monitor set could not be determined
Database problem: The monitor set could not be read and written to the
database.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RA174
- Data for the source monitor set could not be determined ?The SAP error message RA174, which states "Data for the source monitor set could not be determined," typically occurs in the context of the SAP Controlling (CO) module, particularly when dealing with internal orders, cost centers, or other controlling objects. This error indicates that the system is unable to find the necessary data for the specified source monitor set, which is essential for processing certain transactions or reports.
Causes:
- Missing Configuration: The source monitor set may not be properly configured in the system. This could be due to missing entries in the configuration tables or incorrect settings.
- Data Inconsistency: There may be inconsistencies in the data related to the source monitor set, such as missing or incorrect master data.
- Authorization Issues: The user may not have the necessary authorizations to access the data related to the source monitor set.
- Technical Issues: There could be technical issues such as database inconsistencies or problems with the underlying data model.
Solutions:
Check Configuration: Verify the configuration of the source monitor set in the SAP system. Ensure that all necessary settings are correctly defined.
- Navigate to the relevant configuration transaction (e.g., OKKP for controlling area settings) and check the settings for the source monitor.
Validate Master Data: Ensure that all relevant master data (e.g., cost centers, internal orders) is correctly maintained and exists in the system.
- Use transactions like KS01 (Create Cost Center) or KO01 (Create Internal Order) to check if the required data is present.
Review Authorizations: Check if the user encountering the error has the necessary authorizations to access the source monitor set data.
- Use transaction SU53 to analyze authorization issues after the error occurs.
Check for Data Consistency: Run consistency checks to identify any inconsistencies in the data that might be causing the issue.
- Use transaction code KAH3 (Display Cost Center) or similar to check for inconsistencies.
Consult SAP Notes: Look for relevant SAP Notes that may address this specific error. SAP frequently releases notes that provide solutions or workarounds for known issues.
Debugging: If the issue persists, consider debugging the program or transaction that is generating the error to identify the root cause.
Related Information:
By following these steps, you should be able to identify the cause of the RA174 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
RA173
Monitor &1 does not exist in monitor set &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RA172
Entries to copy monitor are not complete
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RA175
Unable to determine data for the target monitor set
What causes this issue? Database problem: The monitor set could not be read and written to the database.System Response The system issues an error m...
RA176
The copy required could not be executed
What causes this issue? The basic monitors for monitor sets concerned are not identical.System Response The system issues an error message and will ...
Click on this link to search all SAP messages.