Message type: E = Error
Message class: QE - RM-QSS Fehlertexte zur Ergebniserfassung
Message number: 717
Message text: Control limits for track &1 could not be calculated
The control limits for track &V1& on the control chart cannot be
calculated with the existing data.
The function was not carried out.
The procedure depends on the type of track and the type of inspection
characteristic. The following options are available:
In the case of an average value track, the standard deviations of the
samples are required to calculate the limits.
In the case of <ZH>summarized recording</>, you can enter these in the
single screen for the characteristic.
In the case of <ZH>classified recording</> or <ZH>recording of
individual values</>, the standard deviation is only determined
automatically during the valuation. In order to initiate the
calculation before the valuation is performed, call the function for
recording the statistical moments.
In the case of an average value track for an acceptance chart, if the
dispersion is large or the tolerance range is small, then the value
for the upper control limit can sometimes be less than that of the
lower control limit.
If this happens, then you should repeat the calculation at a later
date,when the dispersion has decreased.
Individual algorithms can often require a certain minimum number of
inspection results before a calculation is possible.
The exact requirements depend on the procedure stored for the track in
the Customizing application.
Error message extract from SAP system. Copyright SAP SE.
QE717
- Control limits for track &1 could not be calculated ?The SAP error message QE717, which states "Control limits for track &1 could not be calculated," typically occurs in the context of quality management, particularly when dealing with control charts in SAP Quality Management (QM). This error indicates that the system was unable to compute the control limits for a specific track (or control chart) due to various reasons. Causes: Insufficient Data: The most common reason for this error is that there is not enough data available for the calculation of control limits. Control limits require a certain amount of historical data to be calculated accurately. Incorrect Configuration: The control chart or the associated settings may not be configured correctly. This includes settings related to the type of control chart being used or the parameters defined for the quality characteristic. Missing Master Data: Required master data, such as characteristics or specifications, may be missing or incorrectly defined. Statistical Parameters: The statistical parameters required for the
Get instant SAP help. Sign up for our Free Essentials Plan.
QE716
Track &1 of the control chart does not contain any data
What causes this issue? The track &V1& <ZH> &V2& </> of the control chart called does not contain any data.System Respons...
QE715
SPC criterion and characteristic cannot be combined
What causes this issue? The desired SPC criterion is not compatible with the inspection characteristic. An SPC criterion can only be assigned if the ...
QE718
The SPC characteristic indicator is reset
What causes this issue? You have used a master inspection characteristic in which the <ZH>SPC inspection</> indicator is set to define an...
QE719
The function is not supported
What causes this issue? The function that you selected is not supported in this control chart track. You can, for example, display the process capabi...