Do you have any question about this error?
Message type: E = Error
Message class: PVS0C - Customizing Product Variant Structure (PVS)
Message number: 157
Message text: Reference node &1 was provided without historical maintenance as standard
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
PVS0C157
- Reference node &1 was provided without historical maintenance as standard ?The SAP error message PVS0C157 indicates that a reference node has been provided without historical maintenance as standard. This typically occurs in the context of SAP's Product Variants Configuration (PVC) or similar configuration scenarios where certain nodes or characteristics are expected to have historical data or maintenance records.
Cause:
- Missing Historical Data: The reference node specified in the configuration does not have any historical maintenance data associated with it. This can happen if the node was newly created or if historical data was not properly maintained or transferred.
- Configuration Issues: There may be issues with the configuration settings or the way the reference node is defined in the system.
- Data Integrity Issues: There could be inconsistencies or missing links in the data model that prevent the system from recognizing the historical maintenance for the reference node.
Solution:
- Check Historical Data: Verify if the reference node has historical maintenance data. If not, you may need to create or import the necessary historical records.
- Review Configuration Settings: Go through the configuration settings for the reference node to ensure that it is set up correctly. Check if the node is defined properly in the configuration profile.
- Data Maintenance: If the reference node is supposed to have historical data, ensure that it is maintained correctly in the system. This may involve updating the node or its associated characteristics.
- Consult Documentation: Refer to SAP documentation or help resources for guidance on how to manage reference nodes and historical data in your specific version of SAP.
- Contact SAP Support: If the issue persists, consider reaching out to SAP support for assistance. They can provide more specific guidance based on your system configuration and version.
Related Information:
CU50
(Configuration Profile) or CU60
(Configuration Simulation).By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
PVS0C156
Node &1 was provided without historical maintenance as standard
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PVS0C155
Changes were made with a history for the node type &1
What causes this issue? You can no longer set the nodes to 'Maintenance without history' because nodes of this type have already been creat...
PVS0C158
Node type is used in the model assignment between &1/&2 and &3/&4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PVS0C159
Class &1 of class type &2 for object &3 is not recognized
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.