Do you have any question about this error?
Message type: E = Error
Message class: PK - Production - KANBAN
Message number: 616
Message text: Storage location &1 is assigned to WM managed warehouse &2
You tried to create or change a production supply area using a storage
location that is assigned to an WM-managed warehouse. This is not
possible in a S/4HANA cloud environment.
A storage location can be assigned to a warehouse. This warehouse is
intended to be used for WM (Warehouse Management).
The creation of production supply areas with these kind of storage
locations is not supported.
You have to abort the transaction.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
PK616
- Storage location &1 is assigned to WM managed warehouse &2 ?The SAP error message PK616 indicates that a storage location is assigned to a Warehouse Management (WM) managed warehouse, which can lead to issues when trying to perform certain operations. Here’s a breakdown of the cause, potential solutions, and related information:
Cause:
- Storage Location Assignment: The error occurs when a storage location is linked to a WM-managed warehouse, but the system is trying to perform an operation that is not compatible with this setup. This can happen during goods movements, inventory management, or when trying to create transfer orders.
- Configuration Issues: There may be a misconfiguration in the warehouse management settings or the storage location settings in the system.
Solution:
Check Storage Location Assignment:
- Go to the transaction code
SPRO
and navigate to the following path:Logistics Execution -> Warehouse Management -> Interfaces -> Define Storage Locations for Warehouse Management
- Ensure that the storage location is correctly assigned to the warehouse and that it is intended to be managed by WM.
Review Warehouse Management Settings:
- Ensure that the warehouse is properly configured to manage the storage location. Check if the warehouse is set up to handle the specific types of materials or movements you are trying to process.
Adjust Movement Types:
- If you are trying to perform a movement that is not compatible with WM, consider using a different movement type that is appropriate for WM-managed warehouses.
Consult Documentation:
- Review SAP documentation or help files related to Warehouse Management and storage location configuration to ensure that all settings are correct.
Check for Customizations:
- If there are any custom developments or enhancements in your SAP system, ensure that they are not interfering with standard WM processes.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
LT01
(Create Transfer Order), LT10
(Confirm Transfer Order), and LX01
(Display Inventory).By following these steps, you should be able to identify the cause of the PK616 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
PK615
Production supply area &1 is assigned to WM managed warehouse &2
What causes this issue? You tried to create or change a control cycle using the production supply area given in the error message. This supply area i...
PK614
Material staging indicator &1 cannot be used for control cycle
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PK617
Replenishment location &1 is WM-managed and supply area is initial
What causes this issue? You entered a replenishment storage location (field RepLoc) that is assigned to a WM-managed warehouse, but there is no produ...
PK618
Source storage location must use embedded WM
What causes this issue? For stock transfer strategy with warehouse task, the source storage location must use embedded WM. The entered storage locati...
Click on this link to search all SAP messages.