Do you have any question about this error?
Message type: E = Error
Message class: OC - IS-Oil: BDRP Bulk Distribution Requirement Planning messages
Message number: 832
Message text: No dip pair found to be analyzed in the given time range
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OC832
- No dip pair found to be analyzed in the given time range ?The SAP error message OC832 "No dip pair found to be analyzed in the given time range" typically occurs in the context of SAP's data analysis tools, particularly when working with data related to performance analysis or monitoring.
Cause:
This error message indicates that the system could not find any "dip pairs" within the specified time range for analysis. A "dip pair" generally refers to a pair of data points that show a significant drop (or dip) in performance metrics, which are often analyzed to identify issues or anomalies in system performance.
The possible causes for this error include:
- Incorrect Time Range: The specified time range may not contain any relevant data points that exhibit dips.
- Data Availability: There may be insufficient data collected in the specified time range, or the data may not have been recorded properly.
- Configuration Issues: There could be issues with the configuration of the monitoring tools or data collection settings that prevent the identification of dip pairs.
- No Performance Issues: It is also possible that there were no performance issues during the specified time range, leading to no dip pairs being found.
Solution:
To resolve the OC832 error, you can take the following steps:
Check Time Range: Verify that the time range you are analyzing is correct and that it includes periods where you expect to see performance dips. Adjust the time range if necessary.
Review Data Collection: Ensure that the data collection settings are properly configured and that data is being collected as expected. Check if there are any gaps in the data for the specified time range.
Analyze Different Time Frames: If no dip pairs are found in the current time range, try analyzing a broader or different time frame to see if dip pairs can be identified.
Consult Documentation: Review SAP documentation or help resources related to the specific analysis tool you are using to ensure that you are following the correct procedures.
Check System Performance: If you are expecting to see performance issues, consider checking other monitoring tools or logs to confirm whether there were any performance problems during the specified time.
Contact Support: If the issue persists and you are unable to identify the cause, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to diagnose and resolve the OC832 error effectively.
Get instant SAP help. Start your 7-day free trial now.
OC831
Begin of material assignment must be after & &
What causes this issue? The start of a material segment assignment must be after the last material movement for that material segment.System Response...
OC830
Material assignment only possible with zero stock
What causes this issue? The assignment of a material segment to a tank at a tank storage location is only possible when the stocks at the beginning a...
OC833
End date is in future, no further goods movements are possible
What causes this issue? The start and end of a material assignment require zero stock. That requirement must be met if meaningful analyses are to be ...
OC834
Entered batch & has valuation type &, different from entered Val.type &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.