How To Fix O3362 - Target unit of measure for BSW % is defined at ambient conditions


O3362 - Overview

  • Message type: E = Error

  • Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)

  • Message number: 362

  • Message text: Target unit of measure for BSW % is defined at ambient conditions

  • Show details Hide details
  • What causes this issue?

    The Quantity Conversion Interface (QCI) allows you to calculate target
    quantities that are corrected for BSW content (Volume percentage). In
    order to obtain a consistent result, the transaction quantity has to be
    entered at ambient conditions. The target units of measure, on the other
    hand, should be defined at standard conditions (volumes).
    <ZH>Example</>
    You post a goods movement of 1000 Barrel of crude oil with a BSW of 10
    %. You should enter 1,000 BBL and the material temperature (60 FAH) and
    not 1,000 BB6 (Barrel at 60 FAH). Then, the target quantities will be
    corrected using the BSW % factor. Target units should always be masses
    or volumes at defined standard conditions. If you enter 1,000 BB6
    instead and also have UG6 (gallons at 60 FAH) defined in the unit of
    measure group, the result appears to be inconsistent. The system then
    stores a movement of 1,000 BB6 and 37,800 UG6.
    If you enter 1,000 BBL and a BSW of 10%, the system calculates both the
    900 BB6 and 37,800 UG6 value correctly (if defined in the UoM group) and
    stores these values, in addition to the uncorrected transaction
    quantity of 1,000 BBL.
    If you have also a target unit of measure UGL (gallons at ambient)
    defined, that quantity will be calculated to be 37,800 UGL (since the
    material temperature is 60 FAH). This may appear, although correctly
    calculated, not to be correct. The 1,000 BBL at 60 FAH are including the
    BSW % volume, the 37,800 UGL exclude that volume percentage.

    System Response

    A target unit of measure at ambient has to be calculated. The system
    issues a warning message. Processing can continue. You may want to
    overwrite the calculated value for that unit of measure.

    How to fix this error?

    Confirm the message.

    Procedure for System Administrators

    This message can be customized to appear as an error, warning or
    information message, or not to appear at all.

    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message O3362 - Target unit of measure for BSW % is defined at ambient conditions ?
    The SAP error message O3362 indicates that there is an issue with the target unit of measure for a specific material or product, particularly in the context of a batch management or production process. The error specifically mentions that the target unit of measure for BSW (which typically stands for "Basic Substance Weight" or similar) is defined at ambient conditions, which may not be appropriate for the current context of the transaction or process.
    
    Cause: Incorrect Unit of Measure Configuration: The target unit of measure for the material may not be set up correctly in the material master data. It could be defined for ambient conditions, but the process may require a different unit of measure. Inconsistent Data: There may be inconsistencies in the data related to the material, such as the conversion factors between different units of measure not being defined correctly. Batch Management Settings: If batch management is enabled, the settings for

    Already have an account? Login here!




Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author