Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 255
Message text: Incorrect dimension: BSW requires a unit of dimension "volume proportion"
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
O3255
- Incorrect dimension: BSW requires a unit of dimension "volume proportion" ?The SAP error message O3255, which states "Incorrect dimension: BSW requires a unit of dimension 'volume proportion'," typically occurs in the context of working with batch management or material master data in SAP, particularly when dealing with the characteristics of materials in the context of a bill of materials (BOM) or recipes.
Cause:
This error arises when the system expects a specific unit of measure (UoM) for a characteristic or property, but the provided UoM does not match the expected dimension. In this case, the system is expecting a "volume proportion" for a characteristic related to the BSW (Batch Split Weight) but is receiving a different dimension.
Solution:
To resolve this error, you can follow these steps:
Check Material Master Data:
- Go to the material master data for the relevant material and check the characteristics defined for it.
- Ensure that the characteristic related to BSW is set up correctly with the appropriate unit of measure (UoM) for volume proportion.
Review Characteristics:
- Navigate to the characteristics configuration in the SAP system (transaction code CT04).
- Verify that the characteristic associated with BSW is defined with the correct data type and unit of measure.
Adjust BOM or Recipe:
- If the error occurs while processing a BOM or recipe, check the BOM or recipe configuration to ensure that the components and their respective proportions are defined correctly.
- Make sure that the proportions are expressed in the correct UoM (volume proportion).
Check Customizing Settings:
- If you have custom settings or enhancements, review them to ensure they are not interfering with the expected dimensions for BSW.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance on the BSW and its requirements.
Testing:
- After making the necessary adjustments, test the process again to ensure that the error is resolved.
Related Information:
If the problem persists after following these steps, it may be beneficial to consult with your SAP support team or a functional consultant who specializes in material management or production planning.
Get instant SAP help. Start your 7-day free trial now.
O3254
Dimension "Volume proportion" is missing in table T006D
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3253
SI unit for dimension "volume proportion" is missing in table T006
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3256
Target unit of measure is initial
What causes this issue? The system attempts to convert a quantity between two units of measure (UoM). The target UoM is initial; the conversion is no...
O3257
Product type and density type are not compatible
What causes this issue? You have chosen a product type for natural gas or general gases. For these product types, only density type 3, absolute dens...
Click on this link to search all SAP messages.