Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 226
Message text: QCI: SGERG-88, calculation N2 and CO2 out of range
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
O3226
- QCI: SGERG-88, calculation N2 and CO2 out of range ?The SAP error message O3226 QCI: SGERG-88, which indicates that the calculation for N2 and CO2 is out of range, typically occurs in the context of quality control or process management within SAP systems, particularly in industries like manufacturing or chemical processing.
Cause:
- Data Input Issues: The values for N2 (Nitrogen) and CO2 (Carbon Dioxide) may have been entered incorrectly or are outside the expected range defined in the system.
- Measurement Errors: There could be issues with the sensors or instruments used to measure N2 and CO2 levels, leading to inaccurate readings.
- Configuration Settings: The acceptable range for N2 and CO2 might not be properly configured in the system, leading to valid measurements being flagged as errors.
- Process Variability: Natural variability in the production process could lead to N2 and CO2 levels exceeding the defined limits.
Solution:
- Check Input Values: Review the input values for N2 and CO2 to ensure they are correct and within the expected range.
- Verify Measurement Equipment: Inspect and calibrate the measurement instruments to ensure they are functioning correctly and providing accurate readings.
- Review Configuration Settings: Check the configuration settings in SAP for the acceptable ranges of N2 and CO2. Adjust these settings if necessary to reflect the actual process capabilities.
- Consult Documentation: Refer to the relevant SAP documentation or user manuals for guidance on handling this specific error message.
- Contact Support: If the issue persists, consider reaching out to SAP support or your internal IT team for further assistance.
Related Information:
By addressing the underlying causes and following the suggested solutions, you should be able to resolve the O3226 QCI error and ensure that N2 and CO2 calculations are within the acceptable range.
Get instant SAP help. Start your 7-day free trial now.
O3225
QCI: SGERG-88, calculation N2 out of range
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3224
QCI: SGERG-88, no convergency #2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3227
QCI: SGERG-88, conflicting result for N2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3228
QCI: For conversion goup &, use FMTYP & instead of &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.