Message text: Observed test- or base-pressure is outside the ISO recommended range
You have entered a test pressure value that lies outside the recommended
range specified in ISO 13443:1996(E). The valid range is:
95 < pressure/kPa < 105 or approx.
13.8 < pressure/PSI < 15.2 .
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Depending on the system settings, the conversion will be terminated or
can continue.
You can customize whether this message appears as an error or warning
message (Transaction O591). SAP recommends that this message is set to
be an error message.
Error message extract from SAP system. Copyright SAP SE.
O3208
- Observed test- or base-pressure is outside the ISO recommended range ?The SAP error message O3208, which states "Observed test- or base-pressure is outside the ISO recommended range," typically occurs in the context of pressure testing within the SAP system, particularly in industries such as oil and gas, manufacturing, or any sector that involves pressure equipment.
Cause:
This error indicates that the pressure values recorded during a test or measurement do not fall within the acceptable limits defined by ISO standards. The specific causes can include:
- Incorrect Measurement: The pressure measurement may have been taken incorrectly due to faulty equipment or improper calibration.
- Equipment Malfunction: The pressure testing equipment may be malfunctioning or not functioning as intended.
- Environmental Factors: External factors such as temperature or altitude may affect the pressure readings.
- Data Entry Errors: Incorrect data entry during the testing process can lead to values that fall outside the acceptable range.
- Configuration Issues: The system may not be configured correctly to reflect the appropriate ISO standards for the specific type of pressure test being conducted.
Solution:
To resolve the O3208 error, consider the following steps:
- Verify Measurements: Check the pressure measurement equipment for accuracy and ensure it is calibrated correctly. Re-take the measurements if necessary.
- Check Equipment: Inspect the testing equipment for any signs of malfunction or damage. Replace or repair as needed.
- Review Environmental Conditions: Ensure that the testing environment is controlled and that external factors are accounted for.
- Correct Data Entry: Review the data entered into the system for accuracy. Correct any discrepancies found.
- Configuration Review: Ensure that the SAP system is configured correctly to align with the ISO standards relevant to your industry. This may involve consulting with a system administrator or SAP expert.
- Consult Documentation: Refer to the relevant ISO standards and SAP documentation for specific guidelines on acceptable pressure ranges and testing procedures.
Related Information:
By following these steps, you should be able to identify the root cause of the O3208 error and implement the necessary solutions to resolve it.
Get instant SAP help. Start your 7-day free trial now.
O3207
Observed test- or base-temperature is outside the ISO recommended range
What causes this issue? You have entered a test temperature value that lies outside the recommended range specified in ISO 13443:1996(E). The valid r...
O3206
Select quantity conversion dialog box only with quantity <> zero
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3209
Base density or base heating value is zero; calculation fails
What causes this issue? The system attempted to convert the transaction quantity to a target quantity. The two quantities have a different dimension,...
O3210
Database update of Table & failed, sy-subrc = &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.