Do you have any question about this error?
Message type: E = Error
Message class: MCEX - Extraction Interface LIS/BW
Message number: 180
Message text: XPRA to switch update mode must be restarted
The update mode for some logistics applications could not be
automatically converted from XPRA &V1&.
Follow the instructions in the long text of the warnings specified in
the log. Afterwards, restart the XPRA.
Error message extract from SAP system. Copyright SAP SE.
MCEX180
- XPRA to switch update mode must be restarted ?The SAP error message MCEX180 indicates that an XPRA (eXpert Program for Restructuring Applications) program needs to be restarted in order to switch the update mode. This typically occurs during the execution of a background job or during a system upgrade or migration process.
Cause:
The error usually arises due to one of the following reasons:
- Incomplete Execution: The XPRA program did not complete successfully, possibly due to a system interruption or a previous error.
- Configuration Issues: There may be issues with the configuration settings that prevent the XPRA from switching the update mode.
- Database Locking: The database might be locked or busy, preventing the XPRA from executing properly.
- System Resources: Insufficient system resources (like memory or processing power) can also lead to this error.
Solution:
To resolve the MCEX180 error, you can follow these steps:
Restart the XPRA:
- Go to transaction code SE38 or SA38.
- Execute the XPRA program that caused the error again. You may need to check the specific XPRA name from the error message or logs.
Check Logs:
- Review the logs for the XPRA execution to identify any specific errors that occurred during the previous run. You can check the logs in transaction SLG1 or by using the transaction code SM37 to view job logs.
System Resources:
- Ensure that the system has adequate resources (CPU, memory, etc.) available. If necessary, free up resources or schedule the XPRA to run during off-peak hours.
Database Locks:
- Check for any database locks that might be preventing the XPRA from executing. You can use transaction SM12 to view and manage locks.
Configuration Review:
- Review the configuration settings related to the XPRA and ensure that they are set correctly. This may involve checking the relevant customizing settings in the system.
Consult SAP Notes:
- Look for any relevant SAP Notes that may address this specific error. You can search the SAP Support Portal for notes related to the XPRA you are running.
Contact SAP Support:
- If the issue persists after trying the above steps, consider reaching out to SAP Support for further assistance.
Related Information:
By following these steps, you should be able to resolve the MCEX180 error and successfully switch the update mode.
Get instant SAP help. Start your 7-day free trial now.
MCEX173
Check the installed qRFC version -> Long text
What causes this issue? You have changed the update mode to "Queued Delta". With this method, we expicitly recommend that you install at le...
MCEX172
Cannot make changes to multi-queue parameters for application &1
What causes this issue? You cannot maintain the multi-queue parameter &V1& presently, since there are still deltas that have not been process...
MCEX181
Serialized V3 update setting is obsolete ->long text
What causes this issue? The update mode "Serialized V3 Update" has been set for Logistics application &V1&. This mode is no longer ...
MCEX182
Display mode chosen. Changes will not take place
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.