Message type: E = Error
Message class: M2 - LIS: Generating and updating info structures
Message number: 788
Message text: Communication structure & is incomplete and not active!
Results of the check of communication structure &V1& show that the
communication structure is incomplete and not active.
This can often be the case when your communication structure &V1& is an
IDoc. In IDoc maintenance, reference fields cannot yet be maintained.
Choose the appropriate reference fields from your communication
structure. Your communication structure is then changed accordingly and
activated. You can the complete maintenance of your LIS inbound
interface.
Error message extract from SAP system. Copyright SAP SE.
M2788
- Communication structure & is incomplete and not active! ?The SAP error message M2788, which states "Communication structure & is incomplete and not active," typically occurs in the context of Material Management (MM) or related modules when there is an issue with the communication structure used for data transfer between different components or systems.
Cause: Incomplete Configuration: The communication structure may not have been fully configured or activated in the system. Missing Fields: Required fields in the communication structure may be missing or incorrectly defined. Transport Issues: If the communication structure was recently transported from a development environment to a production environment, it may not have been activated properly. Version Mismatch: There may be a version mismatch between the systems involved in the communication.
Solution: Check Configuration: Go to the relevant transaction (e.g., SPRO) and navigate to the configuration settings for the communication structure. Ensure that all necessary fields are defined and that the structure is complete. Activate the Communication Structure: Use transaction SE11 (Data Dictionary) to check the communication
Get instant SAP help. Sign up for our Free Essentials Plan.
M2787
Communication structure & does not contain a field of type & !
What causes this issue? Your communication structure &V1& does not contain a field of type &V2&. The corresponding reference fields a...
M2786
This combination of reference table and reference field is not allowed!
What causes this issue? The combination of reference table &V1& and reference field &V2& is not permitted for the field &V3& ...
M2789
Incorrect generation of program &
What causes this issue? The main program &V1& for the generated updating function modules cannot be generated due to a syntax error. The erro...
M2790
Function group & already exists!
What causes this issue? The function group &V1& that you specified already exists. A new function group, however, is required for generating ...
Click on this link to search all SAP messages.