Do you have any question about this error?
Message type: E = Error
Message class: LTR2_ES_UTILS - Messages for Embedded Specification Utilities
Message number: 134
Message text: Values of filter &1 could not be written into embedded specification &2
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
LTR2_ES_UTILS134
- Values of filter &1 could not be written into embedded specification &2 ?The SAP error message LTR2_ES_UTILS134 indicates that there is an issue with writing values of a filter into an embedded specification. This error typically occurs in the context of SAP's data modeling or reporting tools, such as SAP BW (Business Warehouse) or SAP HANA.
Cause:
The error can be caused by several factors, including:
- Data Type Mismatch: The values being written may not match the expected data types defined in the embedded specification.
- Invalid Filter Values: The filter values being used may not be valid or may not exist in the context of the embedded specification.
- Authorization Issues: The user may not have the necessary permissions to write to the embedded specification.
- Technical Issues: There may be underlying technical issues, such as database connectivity problems or issues with the SAP system itself.
Solution:
To resolve the error, you can take the following steps:
Check Data Types: Ensure that the values being written to the embedded specification match the expected data types. If there is a mismatch, correct the data types accordingly.
Validate Filter Values: Review the filter values being used and ensure they are valid and applicable to the embedded specification. You may need to adjust the filter criteria.
Review Authorizations: Check the user authorizations to ensure that the user has the necessary permissions to write to the embedded specification. If not, you may need to adjust the user roles or permissions.
Check System Logs: Look into the SAP system logs for any additional error messages or warnings that may provide more context about the issue.
Test with Different Values: If possible, try using different filter values to see if the error persists. This can help identify if the issue is with specific values.
Consult Documentation: Refer to SAP documentation or help resources for more information on the specific embedded specification and its requirements.
Contact SAP Support: If the issue persists after trying the above steps, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to diagnose and resolve the error message LTR2_ES_UTILS134 effectively.
Get instant SAP help. Start your 7-day free trial now.
LTR2_ES_UTILS133
Lookup content has been written into the consuming target &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LTR2_ES_UTILS132
Lookup content has been read from the producing target &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LTR2_ES_UTILS135
No filters or lookups to calculate
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LTR2_ES_UTILS136
Lookup table has been initialized
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.