Message type: E = Error
Message class: IR - PM: IMRC - Measurement Readings and Counters
Message number: 200
Message text: No transfer of measurement/counter readings was defined
The system has given you a list of proposals for the transfer of
<DS:GLOS.measurement_reading>measurement readings</>/
<DS:GLOS.counter_reading>counter readings</>. However, you have not
transferred any of the proposals and/or not made a selection.
A transfer of measurement/counter readings for the previously mentioned
<DS:GLOS.measuring_point>measuring points</>/ <DS:GLOS.counter>counters
</> will not take place for the moment.
You can regenerate the list of proposals at any time by calling up the
function <LS>MR Transfer: Propose Assignment</> in the master data
maintenance of measuring points/counters.
Error message extract from SAP system. Copyright SAP SE.
IR200
- No transfer of measurement/counter readings was defined ?The SAP error message IR200 ("No transfer of measurement/counter readings was defined") typically occurs in the context of the SAP IS-U (Industry Solution for Utilities) module, particularly when dealing with the transfer of measurement or counter readings for utilities like electricity, water, or gas.
Cause:
The error message IR200 indicates that there is no configuration or definition for transferring measurement or counter readings in the system. This can happen due to several reasons:
- Missing Configuration: The necessary configuration for the transfer of measurement readings has not been set up in the system.
- Incorrect Master Data: The master data for the measuring point or device may not be correctly maintained, leading to the system not recognizing the transfer settings.
- Inappropriate Transaction Type: The transaction type used for the reading transfer may not be correctly defined or linked to the measurement point.
- Authorization Issues: The user may not have the necessary authorizations to perform the transfer of readings.
Solution:
To resolve the IR200 error, you can follow these steps:
Check Configuration:
- Go to the configuration settings in SAP IS-U and ensure that the transfer of measurement readings is properly defined. This includes checking the settings for measurement points, devices, and reading types.
- Use transaction code SPRO to access the configuration menu and navigate to the relevant sections for measurement reading transfer.
Verify Master Data:
- Check the master data for the measuring points and devices involved. Ensure that all necessary fields are filled out correctly and that the measurement points are active.
- Use transaction codes like EL31 (for measuring points) or EL30 (for devices) to review and maintain the data.
Review Transaction Types:
- Ensure that the transaction type used for the reading transfer is correctly defined and linked to the measurement point. You can check this in the configuration settings.
Check Authorizations:
- Verify that the user attempting to perform the transfer has the necessary authorizations. This can be checked with the help of your SAP security team.
Consult Documentation:
- Review SAP documentation or notes related to the specific version of IS-U you are using, as there may be additional considerations or updates that apply.
Testing:
- After making the necessary changes, perform a test transfer of measurement readings to ensure that the issue has been resolved.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the IR200 error in your SAP system.
Get instant SAP help. Sign up for our Free Essentials Plan.
IR186
RefMeasPoint has a different dimension -> assignment not possible
What causes this issue? You are trying to assign the current <DS:GLOS.measuring_point>measuring point</> a different reference measuring ...
IR185
The reference MeasPoint does not come from the RefLocation assigned
What causes this issue? The current <DS:GLOS.measuring_point>measuring point</> or the measuring point to be created belongs to a functio...
IR201
Transfer of measurement readings defined for &1 measuring points
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR202
Flag only one measuring point per block
What causes this issue? In the present list, you can select a measuring point/counter for each receiving <DS:GLOS.measuring_point>measuring poi...
Click on this link to search all SAP messages.