Message type: E = Error
Message class: IR - PM: IMRC - Measurement Readings and Counters
Message number: 057
Message text: Conversion of MeasPoint & to a counter (or other way round) not possible
You are trying to carry out one of the following activities:
Convert the current <GL:measuring_point>measuring point</> into a
<GL:counter>counter</>
Convert a counter into a normal measuring point
However, <GL:measurement_document>measurement documents</> have already
been created for the measuring point.
INCLUDE 'KEINE-FUNKTION' OBJECT DOKU ID TX LANGUAGE E
Reverse the existing measurement documents, or create a new measuring
point.
Error message extract from SAP system. Copyright SAP SE.
IR057
- Conversion of MeasPoint & to a counter (or other way round) not possible ?The SAP error message IR057, which states "Conversion of MeasPoint & to a counter (or other way round) not possible," typically occurs in the context of measurement points and counters in SAP's Plant Maintenance (PM) or Utilities (IS-U) modules. This error indicates that there is an issue with the conversion between measurement points and counters, which can arise due to several reasons.
Causes of Error IR057
Incompatible Measurement Point and Counter Types: The measurement point and counter may be of different types that are not compatible for conversion. For example, a measurement point defined for a specific unit of measure may not be convertible to a counter that uses a different unit.
Incorrect Configuration: The configuration settings for measurement points and counters may not be set up correctly in the system. This includes settings in the customizing transactions related to measurement points and counters.
Data Integrity Issues: There may be inconsistencies or missing data in the master data records for the measurement points or counters, leading to conversion issues.
Technical Issues: There could be underlying technical issues, such as missing or incorrect entries in the database tables that manage measurement points and counters.
Solutions to Error IR057
Check Compatibility: Verify that the measurement point and counter you are trying to convert are compatible. Check their types and units of measure to ensure they can be converted.
Review Configuration: Go to the relevant customizing transactions (such as SPRO) and review the configuration for measurement points and counters. Ensure that all settings are correctly defined.
Data Validation: Check the master data for both the measurement point and the counter. Ensure that all required fields are filled out correctly and that there are no inconsistencies.
Use Transaction Codes: Utilize transaction codes like
IK01
(Create Measurement Point),IK02
(Change Measurement Point),IK03
(Display Measurement Point), andIK04
(Delete Measurement Point) to manage measurement points and ensure they are set up correctly.Consult Documentation: Refer to SAP documentation or help files for specific guidance on measurement points and counters, as well as any known issues or patches related to this error.
Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. They may provide insights based on the specific version of SAP you are using.
Related Information
By following these steps, you should be able to identify the cause of the IR057 error and implement a solution to resolve it.
Get instant SAP help. Sign up for our Free Essentials Plan.
IR056
Characteristic does not allow a negative valuation
What causes this issue? You have entered a negative value for the lower measurement range limit or minimum total counter reading. However, the charac...
IR055
MeasPoint &1: counter reading falls below minimum total counter reading
What causes this issue? The <GL:counter_reading>counter reading</> or <GL:counter_reading_difference>counter reading difference<...
IR058
Changing the counter direction is no longer possible
What causes this issue? The current <GL:measuring_point>measuring point</> is a <GL:counter>counter</>. You want to change th...
IR059
The counter must run forwards for interval documents
What causes this issue? For the backwards-running <GL:counter>counter</> &V1&, you want to define that the system generate interv...
Click on this link to search all SAP messages.