Do you have any question about this error?
Message type: E = Error
Message class: HRPADCONVERSION - Conversion Class Messages
Message number: 216
Message text: Screen structure &3 specified in table T588UICONVCLAS does not exist
The screen structure &V3& specified in the table T588UICONVCLAS for the
infotype &V1& version &V2& does not exist.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
HRPADCONVERSION216
- Screen structure &3 specified in table T588UICONVCLAS does not exist ?The SAP error message HRPADCONVERSION216 indicates that there is an issue with the screen structure specified in the table T588UICONVCLAS. This error typically arises in the context of HR (Human Resources) module configurations, particularly when dealing with infotypes and their associated screen structures.
Cause:
- Missing Screen Structure: The specified screen structure (denoted as &3 in the error message) does not exist in the system. This could be due to a configuration error, a missing transport, or an inconsistency in the system.
- Incorrect Configuration: The configuration in the infotype or the associated screen may be pointing to a non-existent or incorrectly defined structure.
- Transport Issues: If the system has recently undergone a transport of changes, it is possible that the transport did not include the necessary screen structure or that it was not imported correctly.
Solution:
Check Table T588UICONVCLAS:
- Go to transaction SE11 (Data Dictionary) and check the contents of table T588UICONVCLAS. Look for the entry that corresponds to the infotype or screen structure you are working with.
- Verify if the screen structure specified in the error message exists. If it does not, you may need to create it or correct the entry.
Review Infotype Configuration:
- Use transaction SPRO to navigate to the relevant HR configuration settings. Check the infotype settings and ensure that the screen structure is correctly defined.
- If you have recently made changes to the infotype, ensure that all necessary components are properly configured.
Transport Management:
- If the issue arose after a transport, check the transport logs to ensure that all necessary objects were included and imported correctly.
- If you suspect a transport issue, you may need to re-import the transport or manually create the missing screen structure.
Consult Documentation:
- Review SAP documentation or notes related to the specific infotype or screen structure for any known issues or additional configuration steps that may be required.
Contact SAP Support:
- If the issue persists and you cannot resolve it, consider reaching out to SAP support for assistance. Provide them with the error message details and any relevant configuration information.
Related Information:
By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
HRPADCONVERSION215
More than one entry for MAIN structure (vers. 99) in table T588UICONVCLAS
What causes this issue? Multiple entries exist for the MAIN structure in the table T588UICONVCLAS for the infotype &V1& version 99.System Res...
HRPADCONVERSION214
No entry specified for MAIN structure in table T588UICONVCLAS
What causes this issue? In the table T588UICONVCLAS, no entry exists for the MAIN structure for the infotype &V1& for either the version &...
HRPADCONVERSION217
No messages exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
HRPADCONVERSION218
No entry specified for MAIN structure in table T588UICONVCLAS
What causes this issue? No entry exists for the MAIN structure in the table T588UICONVCLAS for the infotype &V1&.System Response The system ...
Click on this link to search all SAP messages.