How To Fix FTR_COMS076 - &1: Combination of DCS ID &2 and MIC &3 not assigned to commodity &4


SAP Error Message - Details

  • Message type: E = Error

  • Message class: FTR_COMS -

  • Message number: 076

  • Message text: &1: Combination of DCS ID &2 and MIC &3 not assigned to commodity &4

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message FTR_COMS076 - &1: Combination of DCS ID &2 and MIC &3 not assigned to commodity &4 ?

    The SAP error message FTR_COMS076 indicates that there is an issue with the assignment of a DCS (Data Collection System) ID and a MIC (Measurement Instrument Code) to a specific commodity. This error typically arises in the context of commodity trading and risk management within SAP, particularly when dealing with financial transactions related to commodities.

    Cause:

    The error message is triggered when:

    1. The combination of the DCS ID and MIC is not properly assigned to the specified commodity in the system.
    2. There may be missing configuration or incorrect settings in the commodity master data.
    3. The DCS ID or MIC may not be valid or may not exist in the system.
    4. There could be a mismatch in the data entry or a lack of necessary authorizations.

    Solution:

    To resolve the error, you can follow these steps:

    1. Check DCS ID and MIC Assignment:

      • Go to the relevant configuration settings in SAP and verify that the DCS ID and MIC are correctly assigned to the commodity in question.
      • You can do this by navigating to the commodity master data and checking the settings for the specific commodity.
    2. Verify Data Entry:

      • Ensure that the DCS ID and MIC entered in the transaction are correct and match the existing records in the system.
      • Check for any typographical errors or discrepancies in the IDs.
    3. Update Master Data:

      • If the combination is not assigned, you may need to create or update the assignment in the commodity master data.
      • This can typically be done through the transaction codes related to commodity management (e.g., transaction codes for maintaining commodity master data).
    4. Consult Documentation:

      • Review the SAP documentation or help files related to commodity management to ensure that you are following the correct procedures for assigning DCS IDs and MICs.
    5. Check Authorizations:

      • Ensure that you have the necessary authorizations to view and modify the commodity master data. Lack of proper permissions can sometimes lead to issues in data visibility.
    6. Contact Support:

      • If the issue persists after checking the above points, consider reaching out to your SAP support team or consulting with SAP experts for further assistance.

    Related Information:

    • Transaction Codes: Familiarize yourself with relevant transaction codes for managing commodity data, such as CMM1 (Create Commodity Master) or CMM2 (Change Commodity Master).
    • SAP Notes: Check for any SAP Notes related to this error message, as they may provide additional insights or patches that could resolve the issue.
    • Training and Documentation: Ensure that users involved in commodity management are adequately trained on the system and understand how to manage DCS IDs and MICs effectively.

    By following these steps, you should be able to identify and resolve the cause of the FTR_COMS076 error in SAP.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author