Message type: E = Error
Message class: EPRO - Messages for EDM Profile Processing
Message number: 394
Message text: Formula allocation &1 uses &2 as an input profile
You changed the <LS>No Calculation</> field. However, formula
allocation &V1&, which is located one level higher in the hierarchy, is
using output profile &V2& as an input profile.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
To avoid errors during formula calculation, select the <LS>No
Calculation</> field for formula allocation &V3& as well.
Error message extract from SAP system. Copyright SAP SE.
EPRO394
- Formula allocation &1 uses &2 as an input profile ?The SAP error message EPRO394 indicates an issue related to formula allocation in the SAP system, specifically that a formula allocation is using an input profile that is not correctly defined or is causing a conflict. Here’s a breakdown of the cause, potential solutions, and related information:
Cause: Input Profile Issues: The input profile specified in the formula allocation may not exist, may be inactive, or may have been deleted. Configuration Errors: There could be configuration errors in the formula allocation setup, such as incorrect parameters or settings. Data Inconsistencies: There may be inconsistencies in the data that the formula is trying to process, leading to the error. Authorization Issues: The user may not have the necessary authorizations to access the input profile or the formula allocation.
Solution: Check Input Profile: Verify that the input profile specified in the error message exists and is active. You can do this by navigating to the relevant configuration area in SAP
Get instant SAP help. Sign up for our Free Essentials Plan.
EPRO393
The cal. interval does not agree with interval lngth &1 and day offset &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EPRO392
The specified calculation interval is incomplete
What causes this issue? You are performing a synchronous calculation. The last calculation finished with errors. The calculation interval that you en...
EPRO395
Formula allocation &1 is only valid from &2 to &3
What causes this issue? You are performing a synchronous calculation. The calculation interval you entered is not within the validity period of the f...
EPRO396
Enter either a profile or a constant value
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.