Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: EPRO - Messages for EDM Profile Processing
Message number: 346
Message text: Unit of measurement &1 of output profile &2 is incorrect
Unit of measurement &V1& of output profile &V2& does not match the unit
of measurement of output profile &V3&. All output profiles of a profile
value category must be identical.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_KORR OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
EPRO346
- Unit of measurement &1 of output profile &2 is incorrect ?The SAP error message EPRO346 indicates that there is an issue with the unit of measurement (UoM) defined in the output profile for a specific material or product. This error typically arises in the context of production planning, inventory management, or logistics when the system encounters an unexpected or incorrect unit of measurement.
Cause:
- Incorrect Unit of Measurement: The unit of measurement defined in the output profile does not match the expected or allowed units for the material or product.
- Configuration Issues: There may be a misconfiguration in the output profile settings or in the material master data.
- Data Inconsistencies: The unit of measurement in the output profile may not be consistent with the units defined in the material master or other related master data.
- Missing or Incorrect Settings: The output profile may not have been set up correctly, or the necessary settings for the unit of measurement may be missing.
Solution:
Check Output Profile Settings:
- Navigate to the output profile configuration in SAP (transaction code: NACE or SPRO).
- Verify that the unit of measurement defined in the output profile is correct and matches the expected UoM for the material.
Review Material Master Data:
- Check the material master data (transaction code: MM03) for the specific material associated with the output profile.
- Ensure that the unit of measurement in the material master is correctly defined and corresponds to the output profile.
Adjust Configuration:
- If necessary, adjust the configuration settings for the output profile to ensure that the correct unit of measurement is being used.
- Make sure that the output type and associated settings are properly configured.
Consult Documentation:
- Review SAP documentation or help resources related to output profiles and units of measurement for additional guidance.
Testing:
- After making changes, perform tests to ensure that the error does not reoccur and that the output profile functions as expected.
Related Information:
By following these steps, you should be able to identify the cause of the EPRO346 error and implement a solution to resolve it.
Get instant SAP help. Sign up for our Free Essentials Plan.
EPRO345
The input profiles do not have the same units of measurement
What causes this issue? Unit of measurement &V1& of input profile &V2& does not match the unit of measurement of input profile &V...
EPRO344
Profile &1 is already temporarily allocated to output parameter &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EPRO347
Input profile &2 has incorrect unit of measurement &1
What causes this issue? Unit of measurement &V1& of input profile &V2& cannot be converted into unit of measurement &V3& of o...
EPRO348
A constant value will be used for all input parameters
What causes this issue? All the input parameters you have entered use a constant value. This is not permitted. You must allocate a an input profile t...
Click on this link to search all SAP messages.