Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: EMDUS -
Message number: 121
Message text: No variant with simulation for TOU interface with external profile values
In schema &v1&, the variant &v2& is used, which accesses simulation of a
period internally in the system. During billing of profile values in an
external system using a TOU interface, the simulation can calculate
consumptions that are not the same as the actual consumptions.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_VERARB OBJECT DOKU ID TXWhen billing profile values in an external system using a TOU interface,
do <ZH>not</> use the variants QUANTI26, COMPUT26 and COMPUT27.
Error message extract from SAP system. Copyright SAP SE.
EMDUS121
- No variant with simulation for TOU interface with external profile values ?The SAP error message EMDUS121 indicates that there is no variant available for simulation in the Time of Use (TOU) interface when using external profile values. This error typically arises in the context of energy management or billing processes where TOU pricing is applied.
Cause:
- Missing Variant: The primary cause of this error is that the system is unable to find a variant that matches the criteria for the simulation. Variants are often used to store specific settings or configurations for processing data.
- Incorrect Configuration: There may be a misconfiguration in the TOU settings or the external profile values that are being used.
- Data Issues: The external profile values may not be correctly defined or may not exist in the system.
- Authorization Issues: The user may not have the necessary permissions to access the required variants or data.
Solution:
- Check Variants: Verify that the required variant for the TOU interface exists. You can do this by navigating to the relevant transaction in SAP and checking the available variants.
- Create or Modify Variant: If the variant does not exist, you may need to create a new one or modify an existing variant to ensure it meets the requirements for the simulation.
- Review Configuration: Check the configuration settings for the TOU interface and ensure that they are correctly set up to use the external profile values.
- Validate External Profile Values: Ensure that the external profile values being used are correctly defined and available in the system.
- Check Authorizations: Ensure that the user executing the transaction has the necessary authorizations to access the required data and variants.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on the TOU interface and variants.
Related Information:
SE38
(ABAP Editor) or SE11
(Data Dictionary) to check for variants and configurations.By following these steps, you should be able to identify the root cause of the EMDUS121 error and implement a solution to resolve it.
Get instant SAP help. Sign up for our Free Essentials Plan.
EMDUS120
Profile &1: Rate data for simulation is inconsistent
What causes this issue? During the billing simulation, the system established that the rate data is not unique for the profile &v1& for the e...
EMDUS119
TOU interface &1: Consumption pattern has not been maintained
What causes this issue? The billing simulation assumes that you have entered the <DS:DE.E_CONSPAT>consumption pattern</> for the <DS:D...
EMDUS122
Define the total quantity on the time-of-use periods tab page
What causes this issue? This TOU interface is defined to be used to <LS>bill profile values in the external system</>, and a <DS:DE.E_...
EMDUS123
Define a unique total quantity in the period as of &1
What causes this issue? This TOU interface is defined to be used to bill profile values in the external system, and a <DS:DE.E_CONSPAT>consumpt...
Click on this link to search all SAP messages.