Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 586
Message text: Device &1 MR date &2: No validation as no final quantity determined
You want to carry out validations on the meter reading result for device
&V1& with meter reading date &V2&. In meter reading data processing
(table TE410), the <DS:DE.E_QDPLCHECK>Validation for Final Quantity</>
field should be selected for company code &V3& and division &V4&.
Therefore, other independent validations can only take place once a
final quantity has been determined for this meter reading result.
There are a number of reasons why a final quantity cannot be determined.
For more information, see <DS:GLOS.4CE4CC5CAB4243AFE10000000A421391>
final quantity</>.
The other independent validations cannot take place at this time.
The meter reading result must be deferred for processing at a later
time.
A quantity determination trigger has been generated for this meter
reading result, which flags it for quantity determination at a later
time. Process the quantity determination triggers to determine a final
quantity and then execute the validations again.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL586
- Device &1 MR date &2: No validation as no final quantity determined ?The SAP error message EL586 indicates that there is an issue with the validation of a device's measurement reading due to the absence of a final quantity. This error typically occurs in the context of device management and measurement document processing, particularly in industries that rely on utility management or similar processes.
Cause:
The error message EL586 can be triggered by several factors, including:
- Incomplete Measurement Document: The measurement document may not have been fully processed, leading to the absence of a final quantity.
- Incorrect Configuration: There may be issues with the configuration of the device or the measurement point, which can prevent the system from determining a final quantity.
- Missing Data: Required data for the measurement reading may be missing or incorrectly entered, leading to the inability to validate the measurement.
- Timing Issues: The measurement date may not align with the expected processing periods, causing the system to not recognize the measurement as valid.
Solution:
To resolve the EL586 error, consider the following steps:
Check Measurement Document: Review the measurement document associated with the device and ensure that all required fields are filled out correctly. Make sure that the final quantity is determined and recorded.
Validate Device Configuration: Ensure that the device and measurement point configurations are correct. Check for any inconsistencies or missing settings that could affect the measurement processing.
Review Data Entry: Verify that all necessary data has been entered correctly. This includes checking for any missing or incorrect entries in the measurement records.
Reprocess Measurement: If the measurement document is incomplete, you may need to reprocess it or create a new measurement document with the correct data.
Consult Documentation: Refer to SAP documentation or help resources for specific guidance on handling measurement documents and device management.
Check for Updates: Ensure that your SAP system is up to date with the latest patches and updates, as some issues may be resolved in newer versions.
Contact Support: If the issue persists after trying the above solutions, consider reaching out to SAP support or your internal IT team for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the EL586 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EL585
No conversion steps available
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL584
Meter reading request for device &1 already sent
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL587
You cannot change check 99 manually
What causes this issue? You attempted to manually change check 99 <LS>Check Whether Quantity is Final</> in the table for independent val...
EL588
Number of meter reading results that match the selection criteria: &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.