How To Fix EL524 - Time variable meter readings cannot be included automatically


SAP Error Message - Details

  • Message type: E = Error

  • Message class: EL - IS-U meter reading data processing

  • Message number: 524

  • Message text: Time variable meter readings cannot be included automatically

  • Show details Hide details
  • What causes this issue?

    You want to reverse meter reading documents or change a move-out date,
    or (directly or within a larger activity) you want to create meter
    reading orders for registers with multiple control groups.
    In the current process, additional multiple meter reading documents
    (other than those directly affected) exist for device &V1& on date &V2&
    (and possibly before, or for other devices).
    The multiple meter reading documents are not reversed automatically or
    automatically adjusted to the changed move-out date using the reference
    date for multiple meter readings. This is because the current process
    does not refer to all relevant installations, or because meter reading
    results have already been entered, and would be lost if the meter
    reading documents were included.

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.

    System Response

    The multiple meter reading documents remain unchanged.

    How to fix this error?

    If you also want to reverse the multiple meter reading documents, note
    the meter readings entered and use the <LS>Reverse Meter Reading</>
    transaction to reverse the meter reading documents separately (from the
    menu, choose <LS>Utilities Industry</> -> <LS>Device Management</> ->
    <LS>Meter Reading</> -> <DS:TRAN.EL37>EL37 - Reversal</>).
    If you have changed the move-out date and want to adjust the reference
    date for multiple meter readings to the move-out date, recall the
    move-out document in change mode (from the menu, choose <LS>Utilities
    Industry</> -> <LS>Customer Service</> -> <LS>Process Execution</> ->
    <LS>Move-Out</> -> <DS:TRAN.EC56E>Change</>).
    If you have already created meter reading orders for existing multiple
    meter reading documents, note that the reference date may no longer be
    valid (or cancel the transaction, reverse the multiple meter reading
    documents before the transaction date, and thenrestart the transaction).
    You can find the reference date for multiple meter readings by using the
    transaction for the manual monitoring of meter reading data (from the
    menu, choose <LS>Utilities Industry</> -> <LS>Device Management</> ->
    <LS>Meter Reading</> -> <LS>Monitoring</> -> <DS:TRAN.EL31>Manual</>)
    and open page 2 of the meter reading document at the top right of the
    screen.

    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message EL524 - Time variable meter readings cannot be included automatically ?

    The SAP error message EL524, which states "Time variable meter readings cannot be included automatically," typically occurs in the context of managing time-based meter readings in SAP IS-U (Industry Solution for Utilities). This error indicates that the system is unable to automatically include time-variable meter readings due to certain conditions not being met.

    Causes:

    1. Incorrect Configuration: The configuration for time-variable meter readings may not be set up correctly in the system.
    2. Missing Data: Required data for processing the meter readings may be missing, such as the time interval or the meter reading type.
    3. Incompatible Meter Reading Type: The meter reading type being used may not support time-variable readings.
    4. Period Closure: The billing period may be closed, preventing any new readings from being processed.
    5. Authorization Issues: The user may not have the necessary authorizations to process the meter readings.

    Solutions:

    1. Check Configuration: Review the configuration settings for time-variable meter readings in the SAP system. Ensure that all necessary parameters are correctly set.
    2. Verify Data: Ensure that all required data for the meter readings is present and correctly entered. This includes checking the time intervals and meter reading types.
    3. Use Correct Meter Reading Type: Make sure that the meter reading type you are using is compatible with time-variable readings.
    4. Open Billing Period: If the billing period is closed, you may need to reopen it or create a new billing period to allow for the inclusion of new meter readings.
    5. Check Authorizations: Verify that the user has the necessary authorizations to perform the actions related to meter readings.

    Related Information:

    • SAP Notes: Check for any relevant SAP Notes that may provide additional insights or patches related to this error.
    • Documentation: Review the SAP documentation for IS-U regarding time-variable meter readings to ensure compliance with best practices.
    • Transaction Codes: Familiarize yourself with relevant transaction codes such as EL31 (Display Meter Reading) or EL30 (Enter Meter Reading) to troubleshoot and manage meter readings effectively.
    • Support: If the issue persists, consider reaching out to SAP support or your internal SAP team for further assistance.

    By addressing the above causes and implementing the suggested solutions, you should be able to resolve the EL524 error in SAP.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant