Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 482
Message text: Meter reader &1 still used in schedule master record for MR unit &2
You tried to delete a meter reader that is still defined in the schedule
master record for the meter reading unit. This is not permitted.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Delete the meter reader from the schedule master record before you
delete it from table TE115.
Error message extract from SAP system. Copyright SAP SE.
EL482
- Meter reader &1 still used in schedule master record for MR unit &2 ?The SAP error message EL482 indicates that a meter reader is still being referenced in the schedule master record for a specific meter reading unit. This typically occurs when you attempt to delete or modify a meter reader that is still associated with an active schedule.
Cause:
- Active Schedule: The meter reader is linked to a schedule that is still active or has not been completed.
- Data Integrity: SAP enforces data integrity rules to prevent the deletion of records that are still in use, which is why you are encountering this error.
Solution:
To resolve the EL482 error, you can follow these steps:
Check Schedule Records:
- Go to the transaction code
EL31
(or the relevant transaction for your version) to view the schedule master records.- Identify the schedule that is using the meter reader in question.
Update or Delete Schedule:
- If the schedule is still active, you may need to complete it or delete it if it is no longer needed.
- If you need to change the meter reader, you will have to first remove the association in the schedule master record.
Change Meter Reader:
- Once the schedule is no longer using the meter reader, you can proceed to change or delete the meter reader as needed.
Check for Dependencies:
- Ensure that there are no other dependencies or references to the meter reader in other records or transactions.
Consult Documentation:
- If you are unsure about the steps or the implications of deleting or modifying records, consult your SAP documentation or reach out to your SAP support team.
Related Information:
EL31
for schedules, EL30
for meter reading units, and EL20
for meter readers.By following these steps, you should be able to resolve the EL482 error and manage your meter readers and schedules effectively.
Get instant SAP help. Start your 7-day free trial now.
EL481
Internal error after calling BAdI 'ISU_MR_EABL_UPD'
What causes this issue? After calling the BAdI the system tried to read the transferred meter reading results from the database. An internal error oc...
EL480
Meter reading order creation for meter reading unit &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL483
You do not have authorization for &1 &2 (activity &3)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL484
You are not authorized to process the specified &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.