How To Fix EL418 - Register &2 does not exist for device &1 on &3


SAP Error Message - Details

  • Message type: E = Error

  • Message class: EL - IS-U meter reading data processing

  • Message number: 418

  • Message text: Register &2 does not exist for device &1 on &3

  • Show details Hide details
  • What causes this issue?

    This error only occurs when meter readings are entered via auto data.
    This occurs in the following cases:
    If meter readings are uploaded using IDocs in category ISU_MR_UPLOAD
    If BAPI method UPLOAD (Object type MTRREADDOC) is used
    If meter readings are migrated
    In this case, the <DS:GLOS.3526BE39AFAB52B9E10000009B38F974>meter
    reading result</> cannot be used because it cannot be assigned to a
    register. This might be the case if the meter reading is from a
    register not found in this device, for example.

    System Response

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.

    How to fix this error?

    Procedure for System Administrators


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message EL418 - Register &2 does not exist for device &1 on &3 ?

    The SAP error message EL418 "Register &2 does not exist for device &1 on &3" typically occurs in the context of SAP IS-U (Industry Solution for Utilities) when there is an issue related to the configuration of a device (like a meter) and its associated registers. Here’s a breakdown of the components of the error message:

    • &1: This represents the device number (e.g., a meter).
    • &2: This represents the register number (e.g., a specific register on the meter).
    • &3: This represents the installation or location where the device is registered.

    Cause

    The error can be caused by several factors:

    1. Missing Register Configuration: The specified register does not exist in the system for the given device. This could be due to incorrect configuration or data entry.
    2. Incorrect Device or Register Assignment: The device may not be correctly assigned to the register, or the register may not be linked to the device in the system.
    3. Data Inconsistency: There may be inconsistencies in the master data or configuration settings in the SAP system.
    4. Technical Issues: There could be issues with the underlying database or application logic that prevent the system from recognizing the register.

    Solution

    To resolve the EL418 error, you can take the following steps:

    1. Check Device and Register Configuration:

      • Go to the device master data in SAP and verify that the device (meter) is correctly configured.
      • Check if the register exists for the specified device. You can do this by navigating to the relevant transaction codes (e.g., IE03 for viewing device data).
    2. Create or Update Register:

      • If the register does not exist, you may need to create it. Use transaction code IE02 to modify the device and add the missing register.
      • Ensure that the register type and other attributes are correctly defined.
    3. Verify Installation Data:

      • Check the installation data to ensure that the device is correctly linked to the installation point. Use transaction code EI01 or similar to review installation details.
    4. Data Consistency Check:

      • Run consistency checks in the system to identify any discrepancies in the master data. This can often be done through specific reports or transaction codes designed for data consistency checks.
    5. Consult Documentation:

      • Review SAP documentation or notes related to the specific error message for any additional guidance or known issues.
    6. Contact SAP Support:

      • If the issue persists after checking the above points, consider reaching out to SAP support for further assistance, especially if it appears to be a technical issue.

    Related Information

    • Transaction Codes: Familiarize yourself with relevant transaction codes such as IE03 (Display Device), IE02 (Change Device), and EI01 (Installation).
    • SAP Notes: Check SAP Notes for any updates or patches that may address this specific error.
    • User Roles and Authorizations: Ensure that you have the necessary authorizations to view and modify device and register data.

    By following these steps, you should be able to identify and resolve the cause of the EL418 error in your SAP system.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.