Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 417
Message text: Device &1 and code &2: No register found
A code was given when uploading the meter readings. If no register
number exists, the register is determined based upon the code.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check the transferred code and compare it with the code of the device.
Error message extract from SAP system. Copyright SAP SE.
EL417
- Device &1 and code &2: No register found ?The SAP error message EL417 indicates that there is an issue with a device and its associated register. Specifically, the message states: "Device &1 and code &2: No register found." This typically occurs in the context of SAP IS-U (Industry Solution for Utilities) when dealing with device management and meter reading.
Cause:
- Missing Register Configuration: The device (meter) may not have any registers configured in the system. Registers are essential for capturing measurement data.
- Incorrect Device Type: The device type may not be compatible with the expected register configuration.
- Data Inconsistency: There may be inconsistencies in the master data for the device, leading to the system not being able to find the associated registers.
- Technical Issues: There could be technical issues in the database or application layer that prevent the system from retrieving the register information.
Solution:
Check Device Configuration:
- Go to the device master data in SAP and verify that the registers are correctly configured for the device in question.
- Ensure that the device type is appropriate and that it supports the required registers.
Create or Update Registers:
- If no registers are found, you may need to create them. This can typically be done in the device master data transaction (e.g., transaction code EAM or similar).
- Ensure that the registers are correctly linked to the device.
Data Consistency Check:
- Perform a consistency check on the device and its registers. This can often be done through specific reports or transactions in SAP that check for data integrity.
- If inconsistencies are found, correct them as necessary.
Consult Documentation:
- Review SAP documentation or notes related to the specific error message for any additional troubleshooting steps or patches that may be required.
Contact Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. They may provide insights based on the specific configuration and version of your SAP system.
Related Information:
By following these steps, you should be able to identify the root cause of the EL417 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EL416
Device &1 and register &2: Negative MR results not permitted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL415
Estimation not advisable for device &1 and register &2
What causes this issue? The meter reading result that must be estimated, was processed during move-in/out or when changing the logical register numbe...
EL418
Register &2 does not exist for device &1 on &3
What causes this issue? This error only occurs when meter readings are entered via auto data. This occurs in the following cases: If meter readings a...
EL419
Auto data for meter reading is entered incorrectly
What causes this issue? The auto data is incomplete. Either the number of the <DS:GLOS.36D14E023F9901E0E10000009B38F9B7>meter reading document&...
Click on this link to search all SAP messages.