Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 415
Message text: Estimation not advisable for device &1 and register &2
The meter reading result that must be estimated, was processed during
move-in/out or when changing the logical register number. The meter
reading reason is either <LS>after move-in/out</> or <LS>after changing
logical register number</>. In these cases the estimation cannot
determine a sensible value and is therefore unreliable.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL415
- Estimation not advisable for device &1 and register &2 ?The SAP error message EL415, which states "Estimation not advisable for device &1 and register &2," typically occurs in the context of energy management and metering within SAP IS-U (Industry Solution for Utilities). This error indicates that the system has determined that it is not advisable to perform an estimation for the specified device and register due to certain conditions.
Causes:
- Data Quality Issues: The system may have detected that the data for the device or register is incomplete, inconsistent, or not reliable enough to perform an estimation.
- Configuration Settings: There may be specific configuration settings in the system that prevent estimation for certain devices or registers.
- Device Status: The device may be in a status that does not allow for estimation (e.g., inactive, disconnected, etc.).
- Historical Data: Lack of sufficient historical data for the device or register may lead to the system's inability to generate a reliable estimation.
- Technical Restrictions: Certain technical restrictions or business rules may be in place that prevent estimation for specific types of devices or registers.
Solutions:
- Check Device and Register Status: Verify the status of the device and register in the system. Ensure that they are active and properly configured.
- Review Configuration Settings: Check the configuration settings related to estimation in the SAP system. Ensure that the settings allow for estimation for the specific device and register.
- Data Validation: Validate the data associated with the device and register. Ensure that all necessary readings and historical data are present and accurate.
- Consult Documentation: Review SAP documentation or notes related to the EL415 error message for any specific guidelines or recommendations.
- Manual Intervention: If automatic estimation is not advisable, consider manually entering the readings or using alternative methods to handle the situation.
- Contact Support: If the issue persists, consider reaching out to SAP support for further assistance, especially if this is a recurring issue.
Related Information:
By following these steps, you should be able to diagnose and address the EL415 error message effectively.
Get instant SAP help. Start your 7-day free trial now.
EL414
Device &1 and register &2: meter reading is in period already billed
What causes this issue? The meter reading result could not be re-estimated on &v3& because the meter reading result is in a period that has a...
EL413
No search criteria defined for division category &1 and billing class &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL416
Device &1 and register &2: Negative MR results not permitted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL417
Device &1 and code &2: No register found
What causes this issue? A code was given when uploading the meter readings. If no register number exists, the register is determined based upon the c...
Click on this link to search all SAP messages.