Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 359
Message text: Device &1, register &2: Meter reading type &3 does not exist
The <DS:DE.ABLESART>Meter reading type</> was not found in table TE436
(user-defined meter reading type for entry) during import of meter
readings in the background (during upload via IDoc, for example).
No reading was entered for meter reading document number &v4&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL359
- Device &1, register &2: Meter reading type &3 does not exist ?The SAP error message EL359 indicates that there is an issue with a meter reading type in the context of device management, specifically for a device and register combination. Here’s a breakdown of the cause, potential solutions, and related information for this error:
Cause: Non-Existent Meter Reading Type: The error occurs when the system is trying to process a meter reading for a device and register, but the specified meter reading type does not exist in the system.
Configuration Issues: The meter reading type may not have been configured correctly in the system, or it may have been deleted or deactivated. Data Entry Errors: There could be a typo or incorrect entry in the meter reading type field when entering data.
Solution: Check Meter Reading Type Configuration: Go to the configuration settings in SAP for meter reading types (transaction code: SPRO). Navigate to the relevant path for meter reading types and ensure that the meter reading type specified
Get instant SAP help. Sign up for our Free Essentials Plan.
EL358
Device &1, register &2: Error during determination due to MR note
What causes this issue? An error occurred during the estimation triggered by meter reading note &v3&. The error occurred during import of met...
EL357
Device &1, register &2: MR note &3 has not been stored
What causes this issue? The <DS:DE.ABLHINW>Meter reading note</> is not stored in Table TE259 (note from meter reader). You cannot enter ...
EL360
Error accessing schedule record of MRU &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL361
Error during analysis of internal structure &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...