Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 319
Message text: &3 % over-estimation factor used for device &1, register &2
If the <DS:DE.UEFAKTOR1>overestimation factor</> in table TE411 has
been configured in excess of the tolerance limit, the meter reading
will fail the tolerance limit validation. If the meter reading was
automatically reset for this reason, release it. If not, it is
plausible.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL319
- &3 % over-estimation factor used for device &1, register &2 ?The SAP error message EL319 indicates that there is an over-estimation factor being applied to a specific device and register in the context of energy management or utility billing. This message typically arises in the context of electricity or utility meter readings, where the system has detected that the estimated consumption is significantly higher than expected.
Cause: Over-Estimation Factor: The error suggests that the system is using an over-estimation factor that exceeds a predefined threshold. This can happen due to: Incorrect configuration of the estimation parameters in the system. Anomalies in the meter readings, such as missing or erroneous data. A significant change in consumption patterns that the system is not accounting for. Data Quality Issues: If the meter data is not being captured correctly or if there are gaps in the data, the system may resort to using an over-estimation factor to calculate consumption. Configuration Errors: The settings for the estimation process may not be correctly
Get instant SAP help. Sign up for our Free Essentials Plan.
EL318
Meter reading results saved
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL317
The billing order for installation &1 cannot be billed yet
What causes this issue? Devices are still assigned to installation &V1&. Either meter reading orders or results are missing for these devices...
EL320
Input value contains invalid values (template: &)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL321
Input value &1 contains no digits (template: &2)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.