Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 283
Message text: Entry of meter reading results not possible
The error was caused by one of the following:
You have not entered any devices in the processing list.
The device does not have any registers (such as a transformer).
The registers of the device are not relevant to meter reading.
You must enter meter reading results when you change the installation
structure.
This is the case if you change the billing factor or the create a
register relationship.
If you change the rate type, you cannot enter meter readings.
You also cannot enter meter readings if you performed a billing-related
installation reversal on the same day.
In this case, the move-in meter readings are deleted. The device is
then no longer allocated to an installation and removal readings are
irrelevant.
This also applies when you reverse a billing-relevant removal.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL283
- Entry of meter reading results not possible ?The SAP error message EL283 ("Entry of meter reading results not possible") typically occurs in the context of the SAP IS-U (Industry Solution for Utilities) module when there is an issue with entering meter readings for a utility service. Here are some common causes, solutions, and related information for this error: Causes: Incorrect Status of the Device: The meter or device may not be in a status that allows for meter reading entries. For example, if the device is marked as "inactive" or "disconnected," readings cannot be entered. Meter Reading Period Issues: The meter reading period may not be open or valid for the entry of new readings. If the period is closed or not yet started, the system will prevent new entries. Authorization Issues: The user may not have the necessary authorizations to enter meter readings for the specified device or location. Technical Issues: There may be technical issues with the SAP system, such
Get instant SAP help. Sign up for our Free Essentials Plan.
EL282
Device &1, register &2: MR status &3 not permissible for action &4
What causes this issue? Processing actions are permitted for the following meter reading statuses: The system issues an error message and will not al...
EL281
Dep. val. 03: Secondary meter cons. is greater than prinary meter cons.
What causes this issue? During dependent validation 03 (serial switching), the system determined that the sum of the consumption by the secondary met...
EL284
Error in device &1, register &2: See long text from previous line
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL285
Not possible to display list with validations
What causes this issue? You wanted to display more detailed information on the plausibility validations. This is not possible, however, possibly beca...