Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 269
Message text: Dependent validation 05: Cosine phi not within tolerance limits
The meter reading result failed dependent validation 05 (comparison of
cosine with previous period). The cosine phi of the meter reading
result exceeds the maximum deviation of cosine phi from the previous
period(s) specified in Customizing.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL269
- Dependent validation 05: Cosine phi not within tolerance limits ?The SAP error message EL269, which states "Dependent validation 05: Cosine phi not within tolerance limits," typically occurs in the context of electrical engineering applications within SAP, particularly when dealing with power factor calculations or electrical measurements.
Cause:
The error is related to the cosine phi (cos f), which is a measure of the phase difference between voltage and current in an AC electrical system. It indicates the power factor of the system. The error message suggests that the calculated value of cosine phi is outside the acceptable tolerance limits defined in the system. This can happen due to:
- Incorrect Measurement Data: The input data for voltage and current measurements may be incorrect or inconsistent.
- Configuration Issues: The settings or parameters in the SAP system related to electrical measurements may not be configured correctly.
- Faulty Equipment: There may be issues with the measuring equipment or sensors that are providing inaccurate readings.
- Calculation Errors: There could be errors in the formulas or algorithms used to calculate the cosine phi.
Solution:
To resolve the EL269 error, you can take the following steps:
- Check Input Data: Verify the input data for voltage and current measurements. Ensure that they are accurate and consistent.
- Review Configuration: Check the configuration settings in the SAP system related to electrical measurements. Ensure that the tolerance limits for cosine phi are set correctly.
- Inspect Equipment: If applicable, inspect the measuring equipment or sensors for any faults or inaccuracies. Replace or recalibrate them if necessary.
- Analyze Calculations: Review the calculations being performed to ensure that they are correct. If there are custom calculations, verify the logic and formulas used.
- Adjust Tolerance Limits: If the current tolerance limits are too strict for your application, consider adjusting them to allow for a wider range of acceptable values.
Related Information:
By following these steps, you should be able to identify the root cause of the EL269 error and implement an appropriate solution.
Get instant SAP help. Start your 7-day free trial now.
EL268
Dependent validation 04: Result below permissible cosine phi of &1
What causes this issue? During dependent validation 04 (cosine of pi validation against lower limit), the system determined that the current <DS:D...
EL267
Dependent validation 01: Absolute permissible deviation was exceeded
What causes this issue? The control registers vary by more than the permissible variance in the last decimal place.System Response The system issues...
EL270
SM order number assignment terminated during order creation
What causes this issue? The error may have been caused by customizing settings for SM order number assignment for meter reading order creation.System...
EL271
Register allocation type &2 does not match validation group &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.