Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 265
Message text: Dependent validation &1: Readings not complete
The dependent plausibility checks could not be performed yet, because
not all the meter readings in the register relationship have been
recorded yet.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL265
- Dependent validation &1: Readings not complete ?The SAP error message EL265, "Dependent validation &1: Readings not complete," typically occurs in the context of the SAP IS-U (Industry Solution for Utilities) module, particularly when dealing with meter readings and validation processes. This error indicates that the system has detected that not all required meter readings have been entered or completed for a specific validation process.
Cause:
- Incomplete Meter Readings: The primary cause of this error is that the required meter readings for a particular period or for a specific device have not been fully entered or are missing.
- Validation Rules: The validation rules set up in the system may require certain readings to be present before the validation can be completed.
- Data Entry Errors: There may be data entry errors or omissions where readings were not recorded correctly or were skipped.
Solution:
- Check Meter Readings: Review the meter readings for the relevant period and ensure that all required readings have been entered. You can do this by navigating to the relevant transaction for meter reading entry (e.g., transaction code EL31).
- Complete Missing Readings: If any readings are missing, enter the required readings to complete the data set.
- Review Validation Rules: Check the validation rules configured in the system to understand what readings are required for the validation process. This can be done in the configuration settings of the IS-U module.
- Re-run Validation: After ensuring that all required readings are entered, re-run the validation process to see if the error persists.
- Consult Documentation: If the issue continues, consult SAP documentation or support for further guidance on the specific validation rules and requirements.
Related Information:
If the problem persists after following these steps, it may be beneficial to reach out to your SAP support team or consult with an SAP expert for further assistance.
Get instant SAP help. Start your 7-day free trial now.
EL264
Device &1, register &2: Incomplete MRs in dependent validation &3
What causes this issue? The system attempted to read a meter reading document from the database in order to perform a dependent validation. However, ...
EL263
Device &1, register &2: no unique MR document determination possible
What causes this issue? During a dependent validation, the meter reading result of a register in a relationship was re-read via the database. The val...
EL266
Dependent validtion 02: Relative permissible deviation was exceeded
What causes this issue? A control meter relationship exists. The consumption of the control registers deviates more than the total of the consumption...
EL267
Dependent validation 01: Absolute permissible deviation was exceeded
What causes this issue? The control registers vary by more than the permissible variance in the last decimal place.System Response The system issues...
Click on this link to search all SAP messages.