Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 258
Message text: Error during determination of weighting of base period
In extrapolation the system attempted to determine the weighting of the
base period for register &V1& of device &V2& in installation &V3&,
meter reading unit &V4&. The result of the calculation was 0. This is
not permissible.
Extrapolation was terminated.
Check the schedule records of the meter reading unit and, if necessary,
the weighting tables of the weighting procedure corresponding to the
register.
Error message extract from SAP system. Copyright SAP SE.
EL258
- Error during determination of weighting of base period ?The SAP error message EL258, which states "Error during determination of weighting of base period," typically occurs in the context of the SAP system's handling of pricing, especially in the area of condition records or pricing procedures. This error can arise during the execution of pricing calculations, particularly when the system is trying to determine the weighting for a base period in a pricing condition. Causes: Missing Configuration: The error may occur if the configuration for the pricing procedure is incomplete or incorrect. This includes missing condition types or incorrect settings in the pricing procedure. Data Issues: There may be missing or incorrect data in the master data (e.g., material master, customer master) or transaction data (e.g., sales order, purchase order) that is required for the pricing calculation. Custom Code: If there are custom enhancements or user exits that modify the standard pricing logic, they may introduce errors that lead to this message. Versioning Issues:
Get instant SAP help. Sign up for our Free Essentials Plan.
EL257
Device &1, register &2: correcting entry error not advisable
What causes this issue? The system has detected an input error. Since this does not have anything to do with a plausibility check, it does not make s...
EL256
Device &1: MR documents exist after activity date. Activity denied
What causes this issue? Meter reading documents exist after the transaction date. Additional information: When changing the logical register allocat...
EL259
Interval validation for final billing cannot be carried out
What causes this issue? No control parameters for meter reading result entry have been set for the combination of company code &v1& and divis...
EL260
Fixed validations are always carried out automatically: no entry required
What causes this issue? Inspection points 95, 96, and 97 are fixed inspections. They are always performed automatically, and do not have to be explic...