Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 232
Message text: &1 Device &2, MR date &3 estimated or read by customer more than &4 times
The permitted number of customer meter readings or estimations was
exceeded during validation <LS>04</>. You define the permitted number
in the <LS>Meter reading control</> in the installation.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The meter reading can either be released or deferred for processing at
a later date.
Error message extract from SAP system. Copyright SAP SE.
EL232
- &1 Device &2, MR date &3 estimated or read by customer more than &4 times ?The SAP error message EL232 indicates that a specific device (meter) has had its reading or estimated reading processed more than a specified number of times within a defined period. This is typically related to the management of meter readings in the SAP IS-U (Industry Solution for Utilities) module.
Cause: The error message EL232 is triggered when: A meter reading (MR) for a specific device has been entered or estimated more than the allowed number of times (as defined by the system settings). This can happen due to multiple reasons, such as: Incorrect manual entries by users. System errors or bugs that cause repeated processing of the same reading. A high frequency of estimated readings due to issues with the physical meter or data collection processes.
Solution: To resolve the EL232 error, consider the following steps: Check the Meter Reading History: Review the meter reading history for the device in question to identify how many times readings have been entered or
Get instant SAP help. Sign up for our Free Essentials Plan.
EL231
Validation class &1: permissible upper/lower limits cannot be determined
What causes this issue? It is not possible to determine the upper and lower permissible consumption limits based on the expected rate of consumption....
EL230
Indicator for SM order creation is not unique
What causes this issue? Contradictory indicators were set for the installations &1& and &2&.System Response The system issues an err...
EL233
Error during generation of meter reading orders
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL234
Dev. &1, MR date &2: Enter all devs of an installation for same MR date
What causes this issue? The error was occurred for one of the following reasons: The device has several registers that have to be read on the same da...
Click on this link to search all SAP messages.