Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 231
Message text: Validation class &1: permissible upper/lower limits cannot be determined
It is not possible to determine the upper and lower permissible
consumption limits based on the expected rate of consumption.
Causes:
The set validations are located in table TE219. This table is the basis
for determining upper and lower limits.
no tolerance limit validation has been set
a tolerance limit validation has been set, but no values have been
maintained in the appropriate table (TE121) which means that no values
exist from which upper and lower limits can be drawn.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL231
- Validation class &1: permissible upper/lower limits cannot be determined ?The SAP error message EL231, which states "Validation class &1: permissible upper/lower limits cannot be determined," typically occurs in the context of validation checks in SAP, particularly when dealing with validation classes in the context of master data or transactional data.
Cause:
This error usually arises due to one or more of the following reasons:
Missing Configuration: The validation class specified in the error message may not have been properly configured in the system. This could mean that the permissible limits for the validation class have not been defined.
Data Inconsistency: There may be inconsistencies or missing data in the master data or transactional data that the validation class is trying to validate.
Incorrect Parameters: The parameters or values being passed to the validation class may not be valid or may not correspond to the expected format.
Authorization Issues: Sometimes, the user may not have the necessary authorizations to access the data or configuration related to the validation class.
Solution:
To resolve the EL231 error, you can take the following steps:
Check Validation Class Configuration:
- Go to the configuration settings for the validation class in the SAP system.
- Ensure that the permissible upper and lower limits are defined correctly.
- If necessary, consult with your SAP Basis or configuration team to verify the settings.
Review Master/Transactional Data:
- Check the data that is being validated against the validation class.
- Ensure that all required fields are populated and that the data is consistent.
Validate Parameters:
- Review the parameters being passed to the validation class to ensure they are correct and in the expected format.
Check Authorizations:
- Ensure that the user encountering the error has the necessary authorizations to access the validation class and related data.
Debugging:
- If the issue persists, consider using the debugging tools in SAP to trace the execution of the validation class and identify where the limits cannot be determined.
Consult Documentation:
- Refer to SAP documentation or help resources for specific details about the validation class and its configuration.
Related Information:
By following these steps, you should be able to identify the root cause of the EL231 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EL230
Indicator for SM order creation is not unique
What causes this issue? Contradictory indicators were set for the installations &1& and &2&.System Response The system issues an err...
EL229
Error accessing table TE610 for meter reading reason &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL232
&1 Device &2, MR date &3 estimated or read by customer more than &4 times
What causes this issue? The permitted number of customer meter readings or estimations was exceeded during validation <LS>04</>. You defi...
EL233
Error during generation of meter reading orders
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.