Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 176
Message text: Interval deadline! For device &1, register &2...
A &v3& lower priority already exists for this device within the
interval. The &v3& is suppressed when &4& is saved (due to data in
table V_TE610). If the &v3& to be suppressed is relevant to billing,
this means a trigger already exists and it too is deleted. If the &v3&
is relevant to billing and marked as <ZH>Always to be read</>, only the
corresponding trigger is deleted in the case of suppression.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL176
- Interval deadline! For device &1, register &2... ?The SAP error message EL176 "Interval deadline! For device &1, register &2..." typically occurs in the context of SAP IS-U (Industry Solution for Utilities) when there is an issue with the data collection process for a specific device or register. This error indicates that the system has not received the expected data within a specified time frame, which can lead to issues in billing, reporting, or data analysis.
Causes:
- Communication Issues: There may be a problem with the communication between the data collection device (e.g., a meter) and the SAP system. This could be due to network issues, device malfunctions, or configuration errors.
- Data Collection Configuration: The configuration settings for data collection intervals may not be set correctly, leading to missed deadlines for data retrieval.
- Device Malfunction: The physical device (e.g., a meter) may be malfunctioning or not sending data as expected.
- System Performance: High system load or performance issues may delay the processing of incoming data, causing the deadline to be missed.
Solutions:
- Check Device Status: Verify the status of the device or register in question. Ensure that it is operational and correctly configured.
- Review Communication Settings: Check the communication settings between the device and the SAP system. Ensure that there are no network issues or misconfigurations.
- Adjust Data Collection Intervals: Review and, if necessary, adjust the data collection intervals in the configuration settings to ensure they align with the expected data retrieval times.
- Monitor System Performance: Check the performance of the SAP system to ensure it can handle the data load. If necessary, optimize the system or schedule data collection during off-peak hours.
- Error Logs: Review error logs and system messages for additional context or related errors that may provide more insight into the issue.
Related Information:
By following these steps, you should be able to identify the root cause of the EL176 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EL175
Interval deadline! For device &1, register &2...
What causes this issue? A &v3& of higher priority already exists for this device in the interval. You selected <LS>Always read</>...
EL174
No meter reading for device &1 register &2 due to meter reading interval
What causes this issue? A &v3& has already been carried out for this device within the interval specified for the meter reading unit. The cur...
EL177
No interval check carried out for device &1, register &2
What causes this issue? Several meter reading results were found within the interval. This could result in an error that cannot be corrected via stan...
EL178
Device &1, reg. &2: Implausible previous MR results cannot be corrected
What causes this issue? Meter reading results with implausible previous results cannot released.System Response The system issues an error message a...
Click on this link to search all SAP messages.