Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 153
Message text: Check class may still be used in rates
Independent validations of a register are controlled using the
validation class of a rate.
If you delete a validation class and corresponding tolerance limits and
validation parameters, no independent validation will occur for future
meter reading entries.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EL153
- Check class may still be used in rates ?The SAP error message EL153, which states "Check class may still be used in rates," typically occurs in the context of the SAP Convergent Charging (SAP CC) or SAP Convergent Invoicing (SAP CI) modules. This error indicates that a check class, which is a classification used for various checks in the billing or charging process, is still being referenced in existing rates or pricing conditions.
Cause:
The error is usually caused by one of the following reasons:
- Active References: The check class is still being used in one or more rate definitions or pricing conditions, which prevents it from being deleted or modified.
- Incomplete Deactivation: The check class may have been marked for deletion or deactivation, but there are still active references in the system.
- Configuration Issues: There may be configuration settings that are not aligned, leading to the system not recognizing that the check class is no longer needed.
Solution:
To resolve the EL153 error, you can follow these steps:
Identify Active References:
- Use transaction codes like
SE11
(Data Dictionary) orSE16
(Data Browser) to check the database tables related to rates and pricing conditions.- Look for any entries that reference the check class in question.
Remove or Update References:
- If you find that the check class is still being used in rates, you will need to either remove it from those rates or update the rates to use a different check class.
- Navigate to the relevant configuration or rate maintenance transactions to make the necessary changes.
Check Configuration:
- Review the configuration settings in the SAP system to ensure that the check class is not inadvertently linked to any active processes.
- Ensure that all related settings are consistent and that there are no lingering references.
Testing:
- After making the necessary changes, test the billing or charging process to ensure that the error no longer occurs and that the system behaves as expected.
Documentation:
- Document any changes made for future reference and to assist other users who may encounter similar issues.
Related Information:
If the issue persists after following these steps, it may be beneficial to consult with an SAP expert or your organization's SAP support team for further assistance.
Get instant SAP help. Start your 7-day free trial now.
EL152
&1: device &2, MR date &3: &4 below minimum tolerance limit
What causes this issue? The dependent validation showed that the meter reading entered exceeded the tolerance limits. Table TE121 is used for determi...
EL151
&1 device &2, MR date &3: &4 exceeds maximum tolerance limit
What causes this issue? The dependent validation showed that the meter reading entered exceeded the tolerance limits. Table TE121 is used for determi...
EL154
Check group may still be used in rate categories or installation data
What causes this issue? The validation group is used to control dependent validations of a register. It is entered in the rate category or individual...
EL155
Device &1 MR date &2: Maximum demand limit exceeded by &3 &4
What causes this issue? Validations have determined that consumption has exceeded the contract demand limit. The limit is stored in an operand that i...
Click on this link to search all SAP messages.