Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 069
Message text: Device &1, register &2: Meter reading type &3 not permitted
If you enter a meter reader, the meter reading type must be in the
category <LS>Meter reading by the utility</>. However, meter reading
type &v3& is in the category <LS>Meter reading by the customer</> or
<LS>Estimation</>.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Enter a meter reading type in the category <LS>Meter reading by the
utility</>.
Error message extract from SAP system. Copyright SAP SE.
EL069
- Device &1, register &2: Meter reading type &3 not permitted ?The SAP error message EL069 indicates that there is an issue with the meter reading type for a specific device and register. This error typically occurs in the context of utilities management, particularly when dealing with meter readings in SAP IS-U (Industry Solution for Utilities).
Cause:
The error message EL069 is triggered when:
- The meter reading type specified is not allowed for the given device (e.g., a meter) and register (e.g., a specific measurement point).
- The configuration settings in the system do not permit the use of the specified meter reading type for the device or register in question.
- There may be a mismatch between the expected meter reading types and the ones configured in the system.
Solution:
To resolve the EL069 error, you can take the following steps:
Check Meter Reading Type Configuration:
- Go to the configuration settings for meter reading types in SAP. Ensure that the meter reading type you are trying to use is allowed for the specific device and register.
- You can check the configuration in transaction code SPRO under:
SAP Customizing Implementation Guide -> Industry Solutions -> Utilities -> Basic Functions -> Meter Reading -> Define Meter Reading Types
Verify Device and Register Settings:
- Check the settings for the device and register in question. Ensure that they are correctly configured to accept the specified meter reading type.
- You can use transaction code EL31 to view the details of the device and its registers.
Review Meter Reading Order:
- If you are processing a meter reading order, ensure that the order is correctly set up and that the meter reading type is valid for the order type.
Consult Documentation:
- Review the SAP documentation or help files related to meter reading types and their configurations to ensure compliance with the expected settings.
Testing:
- After making any changes, perform a test to see if the error persists. If it does, further investigation may be required.
Contact SAP Support:
- If you are unable to resolve the issue through configuration changes, consider reaching out to SAP support for assistance.
Related Information:
Transaction Codes:
SAP Notes:
User Roles:
By following these steps, you should be able to identify the cause of the EL069 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EL068
Internal error: action &1 does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL067
Order creation not permitted: contract is not allocated to installation
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL070
No meter reading orders exist: &1 orders and &2 billing order created
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EL071
Meter reading order to be created suppressed for device &1, register &2
What causes this issue? The meter reading order has been suppressed. This is because, on the same date and for the same meter reading reason, or in t...
Click on this link to search all SAP messages.