Do you have any question about this error?
Message type: E = Error
Message class: EG - IS-U device management
Message number: 042
Message text: Specify a maximum of & windings
The number of default windings you have entered is larger than the
permitted number of windings. The permitted maximum number is defined
in table TE270 (system parameters for lot procedure/certification IS-U
device management
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_KORR OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
EG042
- Specify a maximum of & windings ?The SAP error message EG042, which states "Specify a maximum of & windings," typically occurs in the context of equipment or functional location data in SAP PM (Plant Maintenance) or similar modules. This error indicates that the system has a limit on the number of windings that can be specified for a particular piece of equipment or functional location, and the user has exceeded that limit.
Cause:
- Exceeding Limits: The primary cause of this error is that the user is trying to enter more windings than the system allows. Each equipment or functional location may have a predefined maximum number of windings set in the configuration.
- Configuration Settings: The maximum number of windings is often defined in the system settings or configuration for the specific equipment type or category.
- Data Entry Error: It could also be a simple data entry mistake where the user inadvertently inputs a higher number than intended.
Solution:
- Check Configuration: Review the configuration settings for the equipment or functional location in question. You may need to consult with your SAP administrator or someone with configuration access to verify the maximum allowed windings.
- Adjust Input: If the number of windings entered exceeds the maximum, reduce the number to comply with the limit specified in the error message.
- Consult Documentation: Refer to the SAP documentation or help files related to the specific module you are working in to understand the limits and how they are set.
- Customizing Settings: If necessary and if you have the appropriate permissions, you may need to adjust the maximum windings limit in the system configuration to accommodate your requirements. This should be done with caution and ideally in consultation with your SAP support team.
Related Information:
If the issue persists after following these steps, it may be beneficial to escalate the matter to your SAP support team for further investigation.
Get instant SAP help. Start your 7-day free trial now.
EG040
Enter an I/O group with the same division category as the device category
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EG039
I/O group &1 has been changed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EG044
Command group &1 has been changed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EG045
Command &1 has been changed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.