Do you have any question about this error?
Message type: E = Error
Message class: EEDMIDEGRID - Grid Messages
Message number: 013
Message text: Voltage level &1 does not exist
For the electricity division category, the grid level is equivalent to
the voltage level.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EEDMIDEGRID013
- Voltage level &1 does not exist ?The SAP error message EEDMIDEGRID013 indicates that a specified voltage level does not exist in the system. This error typically arises in the context of electrical engineering or utility management modules within SAP, particularly when dealing with data related to electrical grids, such as in the SAP IS-U (Industry Solution for Utilities) or SAP EAM (Enterprise Asset Management).
Cause:
- Missing Voltage Level Definition: The voltage level you are trying to use in your transaction or configuration does not exist in the system. This could be due to a missing entry in the relevant master data tables.
- Incorrect Configuration: The voltage level may not have been properly configured or activated in the system.
- Data Entry Error: There may be a typographical error in the voltage level you are trying to reference.
Solution:
Check Voltage Level Master Data:
- Navigate to the relevant configuration or master data area in SAP where voltage levels are defined.
- Verify if the voltage level you are trying to use is listed. If it is not, you will need to create it.
Create or Update Voltage Level:
- If the voltage level does not exist, you can create it by following the appropriate steps in the SAP configuration. This usually involves:
- Accessing the relevant transaction (e.g., SPRO for configuration).
- Navigating to the section for defining voltage levels.
- Adding a new entry with the correct voltage level details.
Check for Typographical Errors:
- Ensure that the voltage level you are entering is spelled correctly and matches the existing entries in the system.
Consult Documentation:
- Review any relevant SAP documentation or help files that pertain to the configuration of voltage levels in your specific SAP module.
Contact Support:
- If you are unable to resolve the issue, consider reaching out to your SAP support team or consulting with an SAP expert who can provide further assistance.
Related Information:
SPRO
for configuration or SE11
for data dictionary.By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
EEDMIDEGRID012
Grid level must be voltage level for electrcty division -> Entry too long
What causes this issue? The voltage level is a maximum of 2 bytes long (data element SPEBENE). The system issues an error message and will not allow ...
EEDMIDEGRID011
Division of settlement coord. &1 not compatible with division of grid &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EEDMIDEGRID014
Grid determination not currently possible for electricity division
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EEDMIDEGRID015
Grid level &1 not defined for grid &2
What causes this issue? Grid level &V1& is not defined for grid &V2&. The system issues an error message and will not allow you to co...
Click on this link to search all SAP messages.