Do you have any question about this error?
Message type: E = Error
Message class: EE_QD -
Message number: 102
Message text: Device &1 Reg. &2 MRDate &3: Quantity determination successful
The meter reading result has the quantity determination status <LS>3 -
Quantity Determination Trigger Generated</>.
Quantity determination was executed again for the quantity determination
trigger and the system was able to determine the final quantity.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
If you are in transaction <LS>Monitoring of Meter Reading Data</> (<NP>
EL31</>) or <LS>Process Quantity Determination Trigger</> (<NP>
EQDTRIGGERMA</>):
--> No further action is necessary.
If you are in a different transaction:
--> Save the meter reading result.
Error message extract from SAP system. Copyright SAP SE.
EE_QD102
- Device &1 Reg. &2 MRDate &3: Quantity determination successful ?The SAP error message EE_QD102 typically indicates that there is an issue related to quantity determination in the context of a specific device and registration. This message is often encountered in the SAP IS-U (Industry Solution for Utilities) module, particularly when dealing with meter readings and quantity calculations.
Cause:
The error message EE_QD102 suggests that the quantity determination process was successful, but it may not have produced the expected results or there may be an issue with the data being processed. Common causes for this message include:
- Data Inconsistencies: There may be inconsistencies in the master data related to the device or registration.
- Configuration Issues: The configuration settings for quantity determination may not be set up correctly.
- Missing or Incorrect Meter Readings: The meter readings associated with the device may be missing, incorrect, or not in the expected format.
- Timing Issues: The date of the meter reading (MRDate) may not align with the expected periods for quantity determination.
Solution:
To resolve the EE_QD102 error, you can take the following steps:
- Check Master Data: Verify the master data for the device and registration. Ensure that all relevant information is accurate and complete.
- Review Configuration: Check the configuration settings for quantity determination in the SAP system. Ensure that the rules and parameters are correctly defined.
- Validate Meter Readings: Ensure that the meter readings are entered correctly and are available for the relevant period. Check for any missing readings or discrepancies.
- Analyze the Date: Confirm that the MRDate is correct and falls within the expected range for quantity determination.
- Consult Logs: Review any logs or detailed error messages that may provide additional context for the issue.
- Test with Sample Data: If possible, test the quantity determination process with sample data to identify if the issue is data-specific or systemic.
Related Information:
EL31
(for meter reading) or EL22
(for device management) to check the relevant data.If the issue persists after following these steps, it may be beneficial to consult with your SAP support team or a consultant who specializes in SAP IS-U for further assistance.
Get instant SAP help. Start your 7-day free trial now.
EE_QD101
Device &1 Reg. &2 MR Date &3: Quantity determination will restart
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EE_QD100
Device &1 register &2: Estimation not poss. due to incorrect qty determ.
What causes this issue? Extrapolation cannot be performed during the estimation, because quantity determination was not performed for one of the asso...
EE_QD103
Quantity determination executed successfully for meter reading results
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EE_QD104
Internal error: New quantity determination cannot be executed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.