Message text: You cannot edit reg. relationship as qty determination has taken place
You have attempted to create or change the register relationship in the
period from &V1& to &V2&. This is not possible as quantity determination
has been successfully executed for at least one of the registers in the
specified period (or later).
You can display the register relationship but you cannot edit it.
You have the following options:
Choose a date as of &V3&.
Reverse the quantity determination in question.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
EE_QD059
- You cannot edit reg. relationship as qty determination has taken place ?The SAP error message EE_QD059, which states "You cannot edit reg. relationship as qty determination has taken place," typically occurs in the context of quantity determination in SAP, particularly when dealing with the configuration of material relationships in the context of the SAP Advanced Planning and Optimization (APO) module or similar areas.
Cause: This error message is triggered when you attempt to edit a relationship (such as a source of supply or a relationship between materials) after the system has already performed quantity determination. Quantity determination is a process where the system calculates the quantities of materials needed based on various factors, such as demand, supply, and planning parameters. Once this process has been executed, the relationships involved are locked for editing to maintain data integrity and consistency.
Solution: To resolve this error, you can consider the following steps: Check Quantity Determination Status: Verify if the quantity determination has indeed been executed. You can check
Get instant SAP help. Sign up for our Free Essentials Plan.
EE_QD057
Only quantity determination procedure for a division allowed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EE_QD056
Internal error accessing table &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EE_QD060
You cannot change rate type, gas proc., fixed temp., vol. corr. factor...
What causes this issue? You attempted to change one of the following fields: Rate Type Gas Procedure Fixed Temperature Volume Correction Factor Consu...
EE_QD061
You are not permitted to change logical reg. no. for reg. &1, device &2
What causes this issue? You attempted to change the logical register number for register &V1& of device &V2& (device category &V3...
Click on this link to search all SAP messages.