Message type: E = Error
Message class: EE_AMI - Message Class for AMI Applications
Message number: 174
Message text: Interval length &1 not permitted; profile billable with TOU interface
You have specified the interval length with ID &V1& even though you have
selected the <LS>TOU Billable</> check box for the profile.
INCLUDE ISU_NOTPOSSIBLE OBJECT DOKU ID TX
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_CHECK OBJECT DOKU ID TX
See the dependencies listed in the documentation for the
<DS:DE.E_TOU_BILLABLE>TOU Billable</> check box.
Error message extract from SAP system. Copyright SAP SE.
EE_AMI174
- Interval length &1 not permitted; profile billable with TOU interface ?The SAP error message EE_AMI174 indicates that there is an issue with the interval length specified in the configuration for a billing profile that uses a Time of Use (TOU) interface. This error typically arises in the context of energy management and billing processes within SAP IS-U (Industry Solution for Utilities).
Cause: The error message "Interval length &1 not permitted; profile billable with TOU interface" suggests that the interval length you are trying to use is not allowed for the specified billing profile. This can happen due to several reasons: Invalid Interval Length: The interval length you are trying to set does not match the allowed values defined in the system for the TOU billing profile.
Configuration Issues: The billing profile may not be properly configured to handle the specified interval length. Profile Restrictions: The billing profile may have restrictions that limit the interval lengths that can be used.
Solution: To resolve this error, you can take
Get instant SAP help. Sign up for our Free Essentials Plan.
EE_AMI173
Day offset &1 not permitted; profile billable with TOU interface
What causes this issue? You have specified day offset &V1& even though you have selected the <LS>TOU Billable</> check box for pr...
EE_AMI172
Consistency chk grp &1 not permitted; profile billable with TOU interface
What causes this issue? You have specified consistency group &V1& even though you have selected the <LS>TOU Billable</> check box...
EE_AMI175
Profile value cat. &1 not permitted; profile billable with TOU interface
What causes this issue? You have specified the profile value category with ID &V1& for the profile even thought you have selected the <LS&...
EE_AMI176
Reference prof. &1 not permitted; profile &2 billable with TOU interface
What causes this issue? You have specified reference profile &V1& even though you have selected the <LS>TOU Billable</> check box...
Click on this link to search all SAP messages.