Do you have any question about this error?
Message type: E = Error
Message class: DT - Table activation (incl. indexes)
Message number: 718
Message text: Base table & of buff. view &: Inactive nametab header not read
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
DT718
- Base table & of buff. view &: Inactive nametab header not read ?The SAP error message DT718, which states "Base table & of buff. view &: Inactive nametab header not read," typically occurs in the context of database views and their associated name tables. This error indicates that the system is unable to read the name table header for a buffered view because the base table is inactive.
Cause:
- Inactive Table: The base table of the buffered view is inactive. This can happen if the table has been modified (e.g., fields added or removed) and the changes have not been activated.
- Buffering Issues: If the buffering settings for the table are not correctly configured, it can lead to issues with reading the name table.
- Transport Issues: If the table was transported from another system and the transport did not include the necessary activation steps, this error may occur.
Solution:
Activate the Base Table:
- Go to the Data Dictionary (transaction SE11).
- Enter the name of the base table that is causing the issue.
- Check if the table is inactive. If it is, activate it by clicking on the "Activate" button.
Check Buffering Settings:
- In transaction SE11, check the buffering settings of the base table.
- Ensure that the buffering is set correctly according to your requirements. If necessary, adjust the buffering settings and activate the table again.
Rebuild the View:
- If the view is still causing issues, consider deleting and recreating the buffered view.
- Ensure that the view is correctly defined and activated.
Transport Considerations:
- If the issue arose after a transport, ensure that all related objects (including the name table) were transported correctly and activated in the target system.
Check for Dependencies:
- Sometimes, other dependent objects may also need to be activated. Check for any dependencies related to the base table and ensure they are all active.
Related Information:
Transaction Codes:
SAP Notes: Check SAP Notes for any known issues or patches related to this error message. You can search for "DT718" in the SAP Support Portal.
Documentation: Review the SAP documentation regarding database views and buffering to understand the implications of changes made to base tables and views.
If the problem persists after trying the above solutions, consider reaching out to your SAP Basis team or SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
DT717
Base table & of buff. view &: Runtime object was not written
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DT716
Base table & of buff. view &: Runtime object could not be read
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DT719
Buffer of table use for view & could not be reset
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
DT720
No technical settings exist for the given table name &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...