Message type: E = Error
Message class: CPOC2 - PP-PI-PMA: PI Sheet Messages, SCM Add-On
Message number: 108
Message text: External event &1 unknown
In the process instruction, a condition is defined that is used to
automatically execute an action (for example, <LS>Deactivate process
instruction</>) in the <DS:GLOS.3526C51EAFAB52B9E10000009B38F974>PI
sheet</> or <DS:GLOS.389B9DAA500F0E7CE10000009B38F931>manufacturing
cockpit</>.
The condition is defined in the form of an event (PPPI_EVENT). However,
the event specified for characteristic PPPI_EVENT does not exist.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check the value assigned to characteristic PPPI_EVENT. Use value help
to prevent typing errors.
Error message extract from SAP system. Copyright SAP SE.
CPOC2108
- External event &1 unknown ?The SAP error message CPOC2108, which states "External event &1 unknown," typically occurs in the context of SAP's Process Orchestration or related modules where external events are being processed. This error indicates that the system has encountered an external event that it does not recognize or cannot process.
Cause: Unrecognized Event: The event identifier (&1) being referenced is not defined in the system. This could be due to a typo, a missing configuration, or an event that has not been properly registered.
Configuration Issues: The external event may not be correctly configured in the system, leading to the inability to recognize it. Integration Issues: If the event is coming from an external system, there may be issues with the integration setup, such as incorrect mapping or communication problems. Version Mismatch: If there are different versions of the software or components involved, it may lead to incompatibility in recognizing certain events.
Solution: Check Event Definition: Verify that the
Get instant SAP help. Sign up for our Free Essentials Plan.
CPOC2107
Parameter X not allowed for PPPI_FORMULA
What causes this issue? In the process instruction, a condition is defined that is used to automatically execute an action (for example, <LS>De...
CPOC2106
No condition defined for PPPI_COMMAND
What causes this issue? You can use a condition (formula, function, or event) to automatically trigger an action (for example, <LS>Activate pro...
CPOC2109
External event &1 not active
What causes this issue? In the process instruction, a condition is defined that is used to automatically execute an action (for example, <LS>De...
CPOC2110
Internal event "Parameter Changed" not permitted here
What causes this issue? An event (PPPI_EVENT) can be used to automatically trigger the following functions in the <DS:GLOS.3526C51EAFAB52B9E100000...