Message type: E = Error
Message class:  CNV_IUUC_REPLICATION - IUUC replication messages (HANA) 
Message number: 149
Message text: Suspending table &1 will affect the following view(s):
Table <(>&<)>1 is associated with one or more views. If you suspend the
initial load or replication process for this table, then these views
will also be suspended.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
The SAP error message CNV_IUUC_REPLICATION149 typically occurs in the context of SAP Landscape Transformation (SLT) replication. This error indicates that suspending a specific table will impact one or more views that depend on that table. Here’s a breakdown of the cause, potential solutions, and related information:
Cause: Table Suspension: The error arises when an attempt is made to suspend a table that is part of a replication setup, and that table is also used in one or more views. Suspending the table would disrupt the data flow to those views. Dependency: The views that depend on the table need the data to function correctly. Suspending the table would lead to inconsistencies or errors in those views.
Solution: Identify Dependencies: Check which views are dependent on the table you are trying to suspend. You can do this by reviewing the database schema or using transaction codes like SE11 (Data Dictionary) to analyze the dependencies. Evaluate Impact: Before
 Get instant SAP help. Sign up for our Free Essentials Plan.
Get instant SAP help. Sign up for our Free Essentials Plan. 
CNV_IUUC_REPLICATION148 The following tables must be stopped:
What causes this issue?  Before the tables can be replicated to the target system, the initial load or replication process must be stopped for these t...
CNV_IUUC_REPLICATION147 First start recording for the following tables:
What causes this issue?  Before the tables can be replicated to the target system, you must start recording data for the tables. You can do this in tr...
CNV_IUUC_REPLICATION150 Logging table &1 for cluster &2 successfully created
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
CNV_IUUC_REPLICATION151 Logging table &1 for table &2 of pool &3 successfully created
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...