Message type: E = Error
Message class: CM_REPORT_TEMPLATE - Report Templates
Message number: 178
Message text: Symbol &1 of the instance control is in the wrong position
An output block was defined for an MIC repeating group (master group
with instance control) or an MIC:POS repeating group (master group -
positions of instance control). However, the symbols for the start
(EHS_ICBCB) and end (EHS_ICBCE) of the output block were swapped. The
report template therefore contains errors and cannot be used for report
generation.
Adjust the sequence of the symbols for the MIC repeating group or the
MIC:POS repeating group in the report template:
EHS_ICBCB: Start of the output block
EHS_ICBCE: End of the output block
Example:
<NP><(><<)>11BRG015(MIC,SAP_EHS_1027_001;*)><(><<)>01EHS_ICBCB></>
[Data for the output block]
<NP><(><<)>01EHS_ICBCE><(><<)>11ERG015></>
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
CM_REPORT_TEMPLATE178
- Symbol &1 of the instance control is in the wrong position ?The SAP error message CM_REPORT_TEMPLATE178 indicates that there is an issue with the positioning of a symbol in the instance control of a report template. This error typically arises when the configuration of the report template does not align with the expected structure or format required by the SAP system.
Cause: Incorrect Symbol Positioning: The symbol (represented by &1 in the error message) is not placed correctly within the report template. This could be due to manual editing or incorrect configuration. Template
Configuration Issues: The report template may have been modified or created incorrectly, leading to misalignment of symbols. Version Compatibility: If the report template was created in a different version of SAP or with different settings, it may not be compatible with the current instance.
Solution: Check Symbol Positioning: Review the report template and ensure that the symbol &1 is placed in the correct position as per the template's design specifications. Refer to the documentation
Get instant SAP help. Sign up for our Free Essentials Plan.
CM_REPORT_TEMPLATE177
Output block not at the start of the MIC repeating group
What causes this issue? An output block was defined for an MIC repeating group (master group with instance control). However, symbol EHS_ICBCB, which...
CM_REPORT_TEMPLATE176
Output block is not fully defined; start is missing
What causes this issue? The output block for an MIC repeating group (master group with instance control) or an MIC:POS repeating group (master group ...
CM_REPORT_TEMPLATE179
Output block not at end of MIC repeating group
What causes this issue? An output block was defined for an MIC repeating group (master group with instance control) or an MIC:POS repeating group (ma...
CM_REPORT_TEMPLATE180
Symbol &1 of instance control occurs more than once in output block
What causes this issue? An error message is output when a new report body is created with the selected report template. An output block in which the ...
Click on this link to search all SAP messages.